Background: The immunocrit is a cost-effective and straightforward technique traditionally used to assess passive immunity transfer to newborn piglets. However, it has not been previously used for monitoring the effect of vaccination and/or infections. Therefore, this study aimed to evaluate the usefulness of the immunocrit technique as an immunological monitoring tool in a vaccination and challenge scenario, using porcine circovirus 2 (PCV-2) as pathogen model. The immunocrit ratio was monitored in PCV-2 vaccinated (V) and non-vaccinated (NV) 3-week-old piglets (study day 0, SD0) that were subsequently challenged with this virus at SD21 and followed up to SD42. Additional techniques (PCV-2 IgG ELISA, optical refractometry, and proteinogram) were performed to further characterize the results of the immunocrit analysis.

Results: Immunocrit, γ-globulin concentration and PCV-2 S/P values followed similar dynamics: descending after PCV-2 vaccination but ascending after an experimental PCV-2 inoculation. However, statistically significant differences between V and NV animals were only found with the PCV-2 ELISA. In this case, V animals had significantly higher (p < 0.05) S/P values (S/P ratio = 0.74) than NV (S/P ratio = 0.39) pigs only after challenge at SD42. On the other hand, serum total protein obtained by refractometer (STPr) were maintained from SD0 to SD21 and increased in both groups from SD21 to SD42. Correlations between techniques were low to moderate, being the most robust ones found between immunocrit and optical refractometry (ρ = 0.41) and immunocrit with γ-globulins (ρ = 0.39). In a subset of sera, the proteinogram technique was applied to the whole serum and the supernatant of the immunocrit, with the objective to characterize indirectly the immunocrit fraction. The latter one included all protein types detectable through the proteinogram, with percentages varying between 64.3% (γ-globulins) and 82% (β-globulins).

Conclusion: The immunocrit technique represented a fraction of the total serum proteins, with low to moderate correlation with all the complementary techniques measured in this study. Its determination at different time points did not allow monitoring the effect of vaccination and/or infection using PCV-2 as a pathogen model.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11342561PMC
http://dx.doi.org/10.1186/s40813-024-00380-yDOI Listing

Publication Analysis

Top Keywords

monitoring tool
8
pcv-2
7
immunocrit
6
immunocrit monitoring
4
tool swine
4
vaccination
4
swine vaccination
4
vaccination infection
4
infection studies?
4
studies? background
4

Similar Publications

Urban-impacted river pollutant sources: WQI ranking and PMF analysis.

Environ Monit Assess

September 2025

School of Materials Engineering, Changzhou Vocational Institute of Industry Technology, Changzhou, 213000, People's Republic of China.

A multi-indicator framework was developed to resolve multi-source pollution in highly urbanized rivers, demonstrated in the Qinhuai River Basin, Nanjing, China. Water quality index (WQI) stratification was integrated with dissolved organic matter (DOM) fluorescence components, hydrochemical ions, and conventional parameters and analyzed using positive matrix factorization (PMF). Correlation analysis further elucidated source compositions and interactions.

View Article and Find Full Text PDF

Transtheoretical Model-based Dietary and Exercise Interventions for Glycemic Control in Type 2 Diabetes: Systematic Review and Meta-analysis.

Nutr Rev

September 2025

Graduate Program in Medical Sciences: Endocrinology, Universidade Federal do Rio Grande do Sul, Porto Alegre, RS, 90035-003, Brazil.

Context: The pillars of diabetes treatment include pharmacotherapy, healthy eating, physical activity, self-monitoring, education, mental health support, and smoking cessation. Interventions based on the Transtheoretical Model of Change, which consider a patient's readiness to behavioral change, may be effective for promoting sustainable self-care. However, the impact of such interventions on diabetes management requires systematic evaluation.

View Article and Find Full Text PDF

Real-world clinical data on the long-term effectiveness and safety of generic racemic ketamine treatment.

J Affect Disord

September 2025

Discipline of Psychiatry and Mental Health, School of Clinical Medicine, University of New South Wales, Sydney, Australia; Ramsay Clinic Northside, St Leonards, Sydney, Australia; Black Dog Institute, Sydney, Australia; The George Institute for Global Health, Sydney, Australia.

Ketamine is a highly effective treatment for difficult-to-treat or treatment-resistant depression (TRD). The commercially developed intranasal spray containing S-ketamine has demonstrated short and long-term efficacy and safety in phase 3 clinical trials leading to regulatory approval for TRD in many countries. Conversely, generic racemic ketamine is prescribed 'off-label'.

View Article and Find Full Text PDF

Timely diagnosing and monitoring of primary graft dysfunction is pivotal for heart transplant patient surveillance. Transthoracic echocardiography is the primary noninvasive method for follow-up of heart transplant recipients, which provides comprehensive information on cardiac morphology and function. It is a sensitive tool in diagnosing rejection, helping to improve therapeutic approaches for this condition, and monitoring cardiac function during therapy.

View Article and Find Full Text PDF

Engineered plasmonic copper (II) sulfide-wrapped polystyrene nanoparticles for spectroscopic detection of mercury ions.

J Hazard Mater

September 2025

Key Lab of Materials Physics, Anhui Key Lab of Nanomaterials and Nanotechnology, Institute of Solid State Physics, HFIPS, Chinese Academy of Sciences, Hefei 230031, China. Electronic address:

We report a novel and highly effective UV-Vis sensing platform based on plasmonic copper (II) sulfide-capsulated polystyrene nanoparticles (PS@CuS NPs) for the rapid, ultrasensitive, and selective detection of Hg . The detection mechanism is driven by a specific anion-exchange reaction between Hg and CuS, resulting in the in-situ transformation of plasmonic CuS into non-plasmonic HgS, which induces a distinct and quantifiable shift in UV-Vis absorption. This structural and optical evolution enables the platform to achieve an exceptionally low detection limit of 20 pM within just 5 min, far below most regulatory thresholds, and a wide linear detection range from 20 pM to 30 nM.

View Article and Find Full Text PDF