A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparative biomechanical analysis of four different tooth- and bone-borne frog appliances for molar distalization : A three-dimensional finite element study. | LitMetric

Comparative biomechanical analysis of four different tooth- and bone-borne frog appliances for molar distalization : A three-dimensional finite element study.

J Orofac Orthop

Key Laboratory of Dental Maxillofacial Reconstruction and Biological Intelligence Manufacturing (NO: 20JR10RA653-ZDKF20210401), School of Stomatology, Lanzhou University, No. 199, Donggang West Road, 730000, Lanzhou, Gansu Province, China.

Published: September 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The purpose of this study was to analyze the biomechanical effects of four different designs of frog appliances for molar distalization using finite element analysis.

Methods: A three-dimensional finite element model including complete dentition, periodontal ligament, palatine, and alveolar bone was established. Four types of frog appliances were designed to simulate maxillary molar distalization: tooth-button-borne (Type A), bone-borne (Type B), bone-button-borne (Type C), and tooth-bone-borne (Type D) frog appliances. A force of 10 N was applied simulating a screw in the anteroposterior direction. To assess the von Mises stress distribution and the resultant displacements in the teeth and periodontal tissues, geometric nonlinear theory was utilized.

Results: Compared to the conventional tooth-borne frog appliance (Type A), the bone-borne frog appliances showed increased first molar distalization with enhanced mesiolingual rotation and distal tipping, but the labial inclination and intrusion of the incisors were insignificant. When replacing the palatal acrylic button with miniscrews (Types B and D), more anchorage forces were transmitted from the first premolar to palatine bone, which was further dispersed by the assistance of a palatal acrylic button (Type C).

Conclusions: Compared to tooth-borne frog appliances, the bone-borne variants demonstrated a clear advantage for en masse molar distalization. The combined anchorage system utilizing palatal acrylic buttons and miniscrews (Type C) offers the most efficient stress distribution, minimizing force concentration on the palatine bone.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00056-024-00535-0DOI Listing

Publication Analysis

Top Keywords

frog appliances
24
molar distalization
20
finite element
12
bone-borne frog
8
appliances molar
8
a three-dimensional finite
8
type a bone-borne
8
stress distribution
8
tooth-borne frog
8
palatal acrylic
8