Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Coronary access (CA) and percutaneous coronary intervention (PCI) might be challenging after valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) with supra-annular self-expanding valves (SS-TAVs) in surgical aortic valves (SAVs). Our study aim was to compare feasibility, predictors, and techniques of CA and PCI following ViV-TAVR with ACURATE neo2 (Boston Scientific, Marlborough, MA) and Evolut PRO+ (Medtronic, Minneapolis, MN).

Methods: Fifteen computed tomography (CT)-based patient-specific aortic models were 3-dimensionally (3D) printed and implanted with specific SAVs and with the 2 SS-TAVs with commissural alignment. Two operators attempted CA (n = 120) and PCI (n = 120) of each coronary artery in a pulsatile-flow-simulator, under real catheterization laboratory conditions. The primary endpoints were the rate of successful CA and PCI. Outcomes with different SS-TAVs were directly compared. An internally mounted borescope camera was used to assess procedures. CT of the models was obtained.

Results: ACURATE neo2 showed significantly higher rates of successful CA (96.7% vs 75%, P = 0.001) and PCI (98.3% vs 85%, P = 0.008) and was associated with a shorter procedural time compared with Evolut PRO+. Independent predictors of unsuccessful CA and PCI were smaller SAV size and Evolut PRO+. The advantage of ACURATE neo2 was mediated by a larger valve-to-anatomy distance at the top of the leaflet plane (11.3 mm vs 4.8 mm), facilitating more often an external cannulation approach for both CA (36.7% vs 15%, P < 0.001) and PCI (36.7% vs 21.7%, P = 0.013).

Conclusions: The rate of successful CA and PCI following ViV-TAVR was higher with ACURATE neo2 compared with Evolut PRO+. The differences in SS-TAVs design affected the cannulation approach and subsequent procedural outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cjca.2024.07.030DOI Listing

Publication Analysis

Top Keywords

acurate neo2
16
evolut pro+
16
pci
9
coronary access
8
transcatheter aortic
8
aortic valve
8
valve replacement
8
pci viv-tavr
8
n = 120
8
rate successful
8

Similar Publications

Background: With transcatheter aortic valve implantation (TAVI) now extending to lower-risk and younger patients, optimizing procedural and hemodynamic outcomes is critical. The Myval Octacor, a new balloon-expandable valve (BEV), was developed to improve outcomes by reducing paravalvular regurgitation (PVL), minimizing pacemaker implantation (PPI) rates, and enhancing hemodynamic performance. However, limited data are available comparing Myval Octacor to contemporary self-expanding supra-annular valves (SEVs) Evolut PRO/PRO+ and Acurate Neo2.

View Article and Find Full Text PDF

The recent voluntary withdrawal of the ACURATE neo2 transcatheter aortic valve replacement device by Boston Scientific offers a compelling case study in the complex interplay of device design, clinical evidence, regulatory requirements, and market dynamics in modern structural heart interventions. Despite promising performance in European and Canadian registries, the ACURATE neo2 valve failed to demonstrate non-inferiority compared with commercially available balloon-expandable and self-expanding platforms in the pivotal ACURATE IDE randomized controlled trial. These results, coupled with introduction of a new regulatory requirements by the European notified body ultimately led to the global discontinuation of the platform.

View Article and Find Full Text PDF

: Aortic stenosis (AS) is the most common valvular heart disease, associated with poor outcomes if left untreated. Current guidelines recommend that transcatheter aortic valve implantation (TAVI) procedures be performed in hospitals with an on-site cardiac surgery unit due to potential complications requiring surgical intervention. : Based on our experience, we evaluated the feasibility and outcomes of implementing a TAVI program in a cardiology department without an on-site cardiac surgery unit, in collaboration with a remote hospital for surgical backup.

View Article and Find Full Text PDF

Background: Recently, Acurate neo2 (ACN2; Boston Scientific, US) and Sapien-3 series (Edwards Lifesciences, US) were compared in the IDE trial failing to demonstrate non-inferiority of ACN2. The Myval series (MyV), an alternative balloon-expandable device, demonstrated non-inferiority compared to Sapien-3 and Evolut (Medtronic, US) in the LANDMARK trial. However, no direct comparison exists between ACN2 and MyV.

View Article and Find Full Text PDF

Stent Frame Underexpansion: A Common Pathway for Failed Interventional Procedures?

J Am Coll Cardiol

July 2025

Department of Cardiovascular Diseases, TUM University Hospital German Heart Center, Technical University Munich University Hospital, Munich, Germany; DZHK (German Center for Cardiovascular Research), Partner Site Munich Heart Alliance, Munich, Germany.

View Article and Find Full Text PDF