A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Deep generative model of the distal tibial classic metaphyseal lesion in infants: assessment of synthetic images. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The classic metaphyseal lesion (CML) is a distinctive fracture highly specific to infant abuse. To increase the size and diversity of the training CML database for automated deep-learning detection of this fracture, we developed a mask conditional diffusion model (MaC-DM) to generate synthetic images with and without CMLs.

Purpose: To objectively and subjectively assess the synthetic radiographic images with and without CMLs generated by MaC-DM.

Materials And Methods: For retrospective testing, we randomly chose 100 real images (50 normals and 50 with CMLs; 39 infants, male = 22, female = 17; mean age = 4.1 months; SD = 3.1 months) from an existing distal tibia dataset (177 normal, 73 with CMLs), and generated 100 synthetic distal tibia images via MaC-DM (50 normals and 50 with CMLs). These test images were shown to 3 blinded radiologists. In the first session, radiologists determined if the images were normal or had CMLs. In the second session, they determined if the images were real or synthetic. We analyzed the radiologists' interpretations and employed t-distributed stochastic neighbor embedding technique to analyze the data distribution of the test images.

Results: When presented with the 200 images (100 synthetic, 100 with CMLs), radiologists reliably and accurately diagnosed CMLs (kappa = 0.90, 95% CI = [0.88-0.92]; accuracy = 92%, 95% CI = [89-97]). However, they were inaccurate in differentiating between real and synthetic images (kappa = 0.05, 95% CI = [0.03-0.07]; accuracy = 53%, 95% CI = [49-59]). The t-distributed stochastic neighbor embedding analysis showed substantial differences in the data distribution between normal images and those with CMLs (area under the curve = 0.996, 95% CI = [0.992-1.000], < .01), but minor differences between real and synthetic images (area under the curve = 0.566, 95% CI = [0.486-0.647], = .11).

Conclusion: Radiologists accurately diagnosed images with distal tibial CMLs but were unable to distinguish real from synthetically generated ones, indicating that our generative model could synthesize realistic images. Thus, MaC-DM holds promise as an effective strategy for data augmentation in training machine-learning models for diagnosis of distal tibial CMLs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11335364PMC
http://dx.doi.org/10.1093/radadv/umae018DOI Listing

Publication Analysis

Top Keywords

synthetic images
12
images
11
classic metaphyseal
8
metaphyseal lesion
8
cmls
8
images cmls
8
cmls generated
8
normals cmls
8
distal tibia
8
normal cmls
8

Similar Publications