A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

"Turn-on" fluorescent sensor for glycerol based on hydrazine-bridged bis-tetraphenylimidazole. | LitMetric

"Turn-on" fluorescent sensor for glycerol based on hydrazine-bridged bis-tetraphenylimidazole.

Spectrochim Acta A Mol Biomol Spectrosc

College of Chemistry and Materials Sciences, Fujian Normal University, Fuzhou 350007, PR China; Fujian provincial Key Laboratory of Advanced Materials Oriented Chemical Engineering, Fuzhou 350007, PR China. Electronic address:

Published: January 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Glycerol is an important biological molecule, but no facile and on-site fluorescence sensor for detecting glycerol has been reported up to now. In this work, the organic fluorescent sensor for glycerol was prepared based on hydrazine-bridged bis-tetraphenylimidazole (HBT), which exhibited an excellent "turn-on" blue fluorescence response in detecting glycerol for the first time. The good sensing selectivity for glycerol among all kinds of organic molecules and ions was confirmed with the low detection limitation (LOD=0.48 μM). The sensing mechanism was proposed as that the photo-induced electron transfer process between the lone pair electrons of the Schiff group and the tetraphenylimidazole moiety was interrupted by the multiple hydrogen-bond action between glycerol and HBT. The sensing ability of HBT for glycerol was successfully used for the detection of glycerol in test paper and real samples (glycerine enema and aloe vera gel), demonstrating the good potential for simple, rapid and in-situ detection of glycerol in daily life.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2024.124951DOI Listing

Publication Analysis

Top Keywords

glycerol
10
fluorescent sensor
8
sensor glycerol
8
based hydrazine-bridged
8
hydrazine-bridged bis-tetraphenylimidazole
8
detecting glycerol
8
detection glycerol
8
"turn-on" fluorescent
4
glycerol based
4
bis-tetraphenylimidazole glycerol
4

Similar Publications