Article Abstract

Background: Metal implants may affect the image quality, iodine concentration (IC), and CT Hounsfield unit (HU) quantification accuracy.

Purpose: To investigate the quantitative accuracy of IC and HU from dual-layer spectral detector (DLCT) in the presence of metal artifacts.

Material And Methods: An experimental cylindrical phantom containing eight iodine inserts and two metal inserts was designed. The phantom underwent scanning at three radiation dose levels and two tube voltage settings. A set of conventional images (CIs), virtual monoenergetic images (VMIs), and iodine concentration maps (ICMs) were generated and measured for all the eight iodine inserts. Quantitative indicators of mean absolute percentage error (MAPE), artifact index (AI), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and standard deviation (SD) on CIs and VMIs were calculated for IC and HU. Subjective score evaluation was also conducted.

Results: The MAPE values of all regions of interest across different scanning configurations were all <5%. Almost all APE values were <5%, indicating that metal artifacts had little impact on IC measurements. When the tube voltage was fixed, the SD value of attenuation decreased with the increase of the tube current; this is also true when the tube current was fixed. The middle energy reconstructions seemed to give a good balance between reducing artifacts and improving contrast.

Conclusion: VMIs from DLCT can reduce metal artifacts, the accuracy of IC quantification is not sensitive to imaging parameters. In summary, metal implants exhibit minimal impact on image quality and IC quantification accuracy in reconstructed images from DLCT.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02841851241269853DOI Listing

Publication Analysis

Top Keywords

iodine concentration
12
dual-layer spectral
8
spectral detector
8
metal implants
8
iodine inserts
8
iodine
5
metal
5
concentration accuracy
4
accuracy metal
4
metal artifacts
4

Similar Publications

Background: Identifying the etiology of acute ischemic stroke (AIS) is critical for secondary prevention and treatment choice in stroke patients. This study aimed to investigate the dual-energy computed tomography (DECT) quantitative thrombus parameters associated with cardioembolic (CE) stroke and develop a nomogram that combines DECT and clinical data to identify CE stroke.

Methods: We retrospectively reviewed all consecutive patients from January 2020 to July 2022 with anterior circulation stroke and proximal intracranial occlusions.

View Article and Find Full Text PDF

With the rapid development of the nuclear medicine business worldwide, the removal of iodine-131 from specific contaminated environments to protect public health has important application prospects. In this study, the surface decontamination mechanism of Ce(IV)/HNO3 as a decontaminant for iodine-131-contaminated nonmetallic materials was investigated by using an orthogonal experimental method and scanning electron microscopy (SEM). During the preparation experiments with the contaminated materials, both quartz glass and ceramics reached peak activity concentration levels at 4 h of adsorption (contamination) by using immersion; the decontamination factor (DF) was selected as the test index for the decontamination experiments.

View Article and Find Full Text PDF

The consumption of kombu plays an important role in the traditional dietary habits of East-Asian countries. However, data on the metabolic profile of kombu-derived iodine remain limited. Totally, 20 Chinese participants (age 19.

View Article and Find Full Text PDF

Introduction: Gestational age, ethnicity, assay method, thyroid autoimmunity and iodine status of the community affect thyroid hormone levels in pregnancy, and there is a need to establish trimester-specific reference ranges for thyroid hormones across different regions of the world. There was no previous study regarding this from this part of the country. The aim of this study was to establish trimester-specific reference range for thyroid hormones during pregnancy in a tertiary care centre in Southern Odisha.

View Article and Find Full Text PDF

Background: Micronutrient deficiencies are common in patients undergoing maintenance hemodialysis (MHD), potentially contributing to adverse clinical outcomes. Hemodiafiltration with endogenous reinfusion (HFR) integrates convection, diffusion, and adsorption, potentially preserving essential nutrients better than traditional online hemodiafiltration (HDF). This study aimed to compare the acute effects of HFR and HDF on serum micronutrient concentrations in MHD patients.

View Article and Find Full Text PDF