Tympanic Cavity Packing in Tympanoplasty Type 1: A Meta-Analysis.

J Coll Physicians Surg Pak

Department of Otorhinolaryngology, University of Malaya Medical Centre, Pantai Dalam, Kuala Lumpur, Malaysia.

Published: August 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Packing of tympanic cavity is generally considered an essential step in myringoplasty. However, each packing material comes with one or another side effect. The objective of this meta-analysis was to compare the results of Type 1 myringoplasty with or without packing. Pubmed, Cochrane database, Embase, Google Scholar, and clinicaltrials.gov were searched using 'tympanoplasty or myringoplasty and packing' as the search query. All RCTs / quasi-RCTs comparing tympanoplasty Type 1 with packing (control) versus without packing (intervention) of tympanic cavity in the human population were included. For dichotomous and continuous outcomes, relative risks (RR) and mean differences (MD) were calculated with 95% confidence interval, respectively. Heterogeneity was assessed using I2 statistics. Publication bias was checked using funnel plot and Egger's test, if applicable. Quality of evidence was assessed for each outcome using GRADE approach. Eleven studies were deemed eligible. For graft uptake and functional success rate, RR of 1.01 and 1.05 were obtained, respectively, showing no significant differences between the intervention and control groups. At 1st and 3rd postoperative month, no-packing group showed 3.86 dB and 2.08 dB better air-bone gap (ABG) closure than the packing group, respectively. Also, intervention with no-packing was 9.28-minute shorter procedure. With RR 0.35, no-packing had significantly lesser postoperative aural fullness. Type 1 tympanoplasty performed with or without packing show comparable results in terms of graft uptake and functional success rate. However, if performed without packing, it takes shorter time, provides early hearing improvement and causes less aural fullness. Key Words: Tympanoplasty Type 1, Packing, Gelfoam, No-packing, Meta-analysis, Endoscopic myringoplasty.

Download full-text PDF

Source
http://dx.doi.org/10.29271/jcpsp.2024.08.956DOI Listing

Publication Analysis

Top Keywords

tympanic cavity
12
tympanoplasty type
12
packing
10
myringoplasty packing
8
type packing
8
graft uptake
8
uptake functional
8
functional success
8
success rate
8
aural fullness
8

Similar Publications

The human auditory system must distinguish relevant sounds from noise. Severe hearing loss can be treated with cochlear implants (CIs), but how the brain adapts to electrical hearing remains unclear. This study examined adaptation to unilateral CI use in the first and seventh months after CI activation using speech comprehension measures and electroencephalography recordings, both during passive listening and an active spatial listening task.

View Article and Find Full Text PDF

Introduction: It is well known that Obstructive Sleep Apnea (OSA) is a complex disease characterized by an Upper Airway (UA) collapse during sleep, with potential consequences on ENT districts. Recent evidence suggests a possible association with Eustachian Tube Dysfunction (ETD). However, the potential effects of both surgical and non-surgical therapeutic strategies on ET function remain poorly explored in the current literature.

View Article and Find Full Text PDF

Purpose: Melbourne rapid fields (MRF) online perimetry is web-based software that allows white-on-white threshold perimetry using any computer. This study assesses the perimetric outcomes of MRF10-2 protocol via laptop computer in comparison to Humphrey field analyzer (HFA).

Methods: This prospective and cross-sectional study included 91 eyes from 91 Japanese glaucoma patients.

View Article and Find Full Text PDF

Objectives: In patients with cochlear implants, tools for measuring intracochlear electric environment as well as neural responses to electrical stimulation are widely available. This study aimed to investigate the possible correlation of changes in the responsiveness of the auditory nerve measured by neural response telemetry with changes in the peak and spread of the intracochlear electric field measured by transimpedance matrix (TIM) in patients implanted with straight electrode arrays.

Design: In this retrospective study, we analyzed a cohort of 144 ears of 113 consecutive patients who were implanted with Slim Straight electrode array (Cochlear Ltd.

View Article and Find Full Text PDF

Clinical efficacy of mepolizumab and dupilumab for eosinophilic otitis media: Analysis of patient clinical characteristic.

Allergol Int

September 2025

Department of Otolaryngology/Deafness and Middle Ear Surgicenter, Tokyo Kita Medical Center, Tokyo, Japan; Department of Otolaryngology - Head and Neck Surgery, Jichi Medical University Saitama Medical Center, Saitama, Japan.

Background: Eosinophilic otitis media (EOM) is characterized by eosinophilic infiltration of the middle ear; it is frequently associated with bronchial asthma and chronic rhinosinusitis with nasal polyposis. Although biologics have been used to treat EOM, their efficacy based on clinical characteristics remains unclear. In this study, we evaluated the effectiveness of biologics and analyzed the clinical factors that influenced outcomes.

View Article and Find Full Text PDF