Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: In 2019, the US Food and Drug Administration (FDA) approved transcatheter aortic valve replacement (TAVR) for low-risk patients with symptomatic severe tricuspid aortic stenosis. However, bicuspid aortic valve (BAV) patients were included only in single-arm registries of pivotal low-risk TAVR trials, resulting in limited data for this subgroup.
Methods: The LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and the first FDA-approved investigational device exemption trial to evaluate the feasibility of TAVR with balloon-expandable or self-expanding valves in low-risk patients with symptomatic severe BAV stenosis. This analysis reports 2-year follow-up, assessing the primary outcome of all-cause mortality and evaluating clinical outcomes.
Results: From 2016 to 2019, a total of 72 low-risk patients diagnosed with symptomatic, severe BAV stenosis underwent TAVR across six centers. Six patients were lost to follow-up. At 2-year follow-up, mortality was 1.5% (1 of 66 patients). Among the remaining 65 patients, four experienced nondisabling strokes (6.2%), while 2 (3.1%) developed infective endocarditis. No new permanent pacemakers were required beyond the 30-day follow-up, and no patients, including those with endocarditis, needed aortic valve re-intervention. At the 2-year echocardiography follow-up (n = 65), 27.8% of BAV patients showed mild aortic regurgitation, with none exhibiting moderate or severe regurgitation. The mean aortic gradient was 12.1 ± 4.1 mmHg, and the mean valve area was 1.7 ± 0.5 cm².
Conclusion: The 2-year follow-up confirms commendable clinical outcomes of TAVR in patients with bicuspid aortic stenosis, establishing its evident safety.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ccd.31170 | DOI Listing |