98%
921
2 minutes
20
IntroductionPolymethylpentene (PMP) oxygenators serve as the primary oxygenator type utilized for ECMO. With the number of PMP oxygenators available, it has become increasingly important to determine differences among each oxygenator type that can lead to varying metrics of oxygenator dysfunction.MethodsThis study was a retrospective, single-center analysis of adult patients supported on ECMO between December 2020 to December 2021 with varying PMP oxygenators including the Medtronic Nautilus Smart (Minneapolis, MA), the Eurosets AMG PMP (Medolla, Italy) and Getinge Quadrox-iD and the Getinge Cardiohelp HLS Module Advanced System (Gothenberg, Sweden).ResultsA total of 19 patients were included in our study. 10 patients (52.6%) were supported with a Medtronic Nautilus Smart oxygenator, 5 patients (26.3%) were supported with an Eurosets AMG PMP Oxygenator, and 4 patients (21.1%) were supported with either a Getinge Quadrox-iD oxygenator or Getinge Cardiohelp HLS system. Patients supported with Eurosets AMG PMP oxygenators experienced higher resistance and lower post-oxygenator PaO in comparison to other cohorts ( < .02 and < .002 respectively). There was no difference in measured oxygen transfer between cohorts ( = .667). Two patients, both supported by Eurosets AMG PMP, experienced oxygenator failure (094).ConclusionRadial flow oxygenators are prone to higher resistance and lower post-oxygenator PaOwhen compared to transverse flow oxygenators. Future larger multicenter studies are required to fully discern the differences between flow-varying polymethylpentene oxygenators and their appropriate cutoffs for oxygenator dysfunction.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/02676591241268402 | DOI Listing |
Front Cardiovasc Med
June 2025
Clinical Research Laboratory, Department of Thoracic and Cardiovascular Surgery, University Hospital Tübingen, Tübingen University, Tübingen, Germany.
Artificial lungs support patients with acute or chronic lung diseases. However, complications such as the activation of blood components leading to thrombosis and inflammation limit their long-term applicability. The systematic characterization of protein adhesion events on different material parts of the oxygenators at different flow rates can shed light on the initial reaction of blood to foreign materials.
View Article and Find Full Text PDFMembranes (Basel)
June 2025
School of Advanced Science and Engineering, Waseda University, 3-4-1 Okubo, Shinjuku-ku 169-8555, Tokyo, Japan.
Long-term ECMOs are expected to be put into practical use in order to prepare for the next emerging severe infectious diseases after the novel coronavirus pandemic in 2019-2023. While polypropylene (PP) and polymethylpentene (PMP) are currently the mainstream materials for the hollow fiber membranes of ECMO, the PP membrane coated with a silicone layer on the outer surface has also been commercialized. In this study, we sought a method to accurately observe the detailed pore morphologies of the PP membrane by suppressing irreversible changes in the morphology in SEM observation, which is a general-purpose observation with higher resolution.
View Article and Find Full Text PDFTher Adv Respir Dis
May 2025
University of Texas Health San Antonio, San Antonio, TX, USA.
Background: Non-idiopathic pulmonary fibrosis interstitial lung diseases (non-IPF ILDs) comprise a broad spectrum of pathologies with varying degrees of inflammation and fibrosis. Progressive fibrosing ILD is associated with significant mortality and limited treatment options. Standard regimens employ multimodal immunosuppression, most commonly prolonged courses of oral corticosteroids (OCS), that are associated with a high risk of adverse effects and limited proven efficacy.
View Article and Find Full Text PDFPerfusion
February 2025
Division of Pediatric Surgery, Department of Surgery, Columbia University Vagelos College of Physicians and Surgeons/NewYork-Presbyterian Morgan Stanley Children's Hospital, New York, NY, USA.
Introduction: Extracorporeal membrane oxygenation (ECMO) is utilized in critically ill neonates with severe cardiopulmonary failure. Hemolysis is a potential complication and is associated with significantly increased morbidity and mortality. The etiology of hemolysis in neonates is multifactorial, including shear forces generated by the ECMO pump, higher flow resistance from smaller tubing and smaller cannulas, the oxygenator, and other patient factors.
View Article and Find Full Text PDFInt J Mol Sci
January 2025
School of Materials Science and Engineering, PCFM Lab, GD HPPC Lab, Sun Yat-sen University, Guangzhou 510275, China.
As a kind of high-performance thermoplastic crystalline resin, poly(4-methyl-1-pentene) (PMP) is characterized by its low density, low dielectric constant, exceptional mechanical and chemical properties, high transparency, and gas permeability. PMP has recently received more attention since COVID-19, because it is used as a hollow-fiber membrane for extracorporeal membrane oxygenation (ECMO) based on its high permeability and excellent biocompatibility. This review summarizes the chemical structure, synthesis, properties, and application of PMP.
View Article and Find Full Text PDF