98%
921
2 minutes
20
Electrochemical sensors provide an affordable and reliable approach towards the detection and monitoring of important biological species ranging from simple ions to complex biomolecules. The ability to miniaturize electrochemical sensors, coupled with their affordability and simple equipment requirements for signal readout, permits the use of these sensors at the point-of-care where analysis using non-invasively obtainable biofluids is receiving growing interest by the research community. This paper describes the design, fabrication, and integration of a 3D printed Mg potentiometric sensor into a 3D printed microfluidic device for the quantification of Mg in low-sample volume biological fluids. The sensor employs a functionalized 3D printable photocurable methacrylate-based ion-selective membrane affixed to a carbon-mesh/epoxy solid-contact transducer for the selective determination of Mg in sweat, saliva and urine. The 3D printed Mg ion-selective electrode (3Dp-Mg-ISE) provided a Nernstian response of 27.5 mV per decade with a linear range of 10 mM to 39 μM, covering the normal physiological and clinically relevant levels of Mg in biofluids. 3Dp-Mg-ISEs selectively measure Mg over other biologically present cations - sodium, potassium, calcium, ammonium - as well as provide high stability in the analytical signal with a drift of just 13 μV h over 10 hours. Comparison with poly(vinylchloride)-based Mg-ISEs showed distinct advantages to the use of 3Dp-Mg-ISEs, with respect to stability, resilience towards biofouling and importantly providing a streamlined and rapid approach towards mass production of selective and reliable sensors. The miniaturization capabilities of 3D printing coupled with the benefits of microfluidic analysis (, low sample volumes, minimal reagent consumption, automation of multiple assays, ), provides exciting opportunities for the realization of the next-generation of point-of-care diagnostic devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4lc00407h | DOI Listing |
Environ Pollut
September 2025
Centre for Environmental and Marine Studies (CESAM) & Department of Biology, University of Aveiro, Portugal. Electronic address:
Printed circuit boards (PCB) present a complex recycling challenge due to their miniaturisation and different constituents (e.g., metals, plastics), highlighting the need for integrated bioprocessing approaches.
View Article and Find Full Text PDFColloids Surf B Biointerfaces
September 2025
School of Mechanical Engineering, Xinjiang University, Urumqi 830017, PR China; Institute of Bioadditive Manufacturing, Jiangxi University of Science and Technology, Nanchang 330013, PR China.
High-performance hydrogel biomaterials hold considerable promise for advanced wound care. However, the suboptimal mechanical properties of conventional hydrogel materials limit their practical application. In this study, Hyaluronic acid sodium salt (HA), xanthan gum (XG), and N-acryloyl-glycinamide (NAGA) hydrogels with porous structures were successfully fabricated using in-situ extrusion 3D printing technology, and a functionalization strategy involving tea polyphenol (TP) immersion was proposed to enhance material properties through additional hydrogen bonding.
View Article and Find Full Text PDFJ Am Soc Mass Spectrom
September 2025
Nontargeted Separations Laboratory, Chemistry Department, William & Mary, Integrated Science Center 1053, 540 Landrum Drive, Williamsburg, Virginia 23188, United States.
Fingerprints are routinely used as evidence in forensic investigations. Fingermarks, any mark left by a donor whether a complete print or not, include sweat and oil excreted by the donor. The chemical components of fingermarks are typically analyzed by gas chromatography-mass spectrometry (GC-MS).
View Article and Find Full Text PDFEur J Ophthalmol
September 2025
vEyes NPO, vEyes Lab, Milo, Italy.
PurposeTo introduce, describe and validate a novel, 3D-printed portable slit lamp system integrated with a macro lens-equipped smartphone, providing clinicians with a quick, easy, and effective method for obtaining high-quality clinical images.Materials and MethodsA 3D-printed portable slit lamp was developed, comprising a warm white LED light pen housed in a custom case with a biconvex lens focusing light through a 0.4 mm slit.
View Article and Find Full Text PDFCereb Cortex
August 2025
Faculty of Psychology and Education Science, Department of Psychology, University of Geneva, Chemin des Mines 9, Geneva, 1202, Switzerland.
Language learning and use relies on domain-specific, domain-general cognitive and sensory-motor functions. Using fMRI during story listening and behavioral tests, we investigated brain-behavior associations between linguistic and non-linguistic measures in individuals with varied multilingual experience and reading skills, including typical reading participants (TRs) and dyslexic readers (DRs). Partial Least Square Correlation revealed a main component linking cognitive, linguistic, and phonological measures to amodal/associative brain areas.
View Article and Find Full Text PDF