98%
921
2 minutes
20
A metanalysis of available randomized controlled trials and observational studies comparing self-expanding (SE) and balloon-expandable (BE) bioprostheses in patients with small aortic annulus and aortic stenosis for short- and midterm hemodynamic and clinical outcomes was performed. A total of 21 studies with a total 8,647 patients (SE: n = 4,336 patients vs BE: n = 4,311 patients) were included. SE bioprostheses had a lower postoperative mean gradient at 30 days (Mean Difference [MD] -5.16, 95% confidence interval [CI] 4.7 to 5.5, p <0.001) and at 1 year (MD -6.6, 95%CI 6.1 to 7.03, p <0.001), with a larger indexed effective orifice area (0.17, 95% CI 0.13 to 0.22, p <0.001 and 0.17, 95% CI 0.08 to 0.27, p <0.001) at both time intervals. BE bioprostheses had a higher risk of 30-day and 1-year severe prosthesis-patient mismatch (risk ratio [RR] 1.07, 95% CI 1.04 to 1.09, p <0.001; RR 1.07, 95% CI 1.04 to 1.11, p <0.001). The 30-day and 1 year paravalvular leaks (RR 0.99, 95% CI 0.98 to 0.99, p <0.001; RR 0.89, 95% CI 0.82 to 0.95, p <0.001) and permanent pacemaker implantation (RR 0.97, 95% CI 0.94 to 0.99, p 0.01, I2 = 40%,) were lower in the BE group. BE bioprostheses were associated with a lower risk of in-hospital stroke (RR 0.99, 95% CI 0.98 to 1, p = 0.01). In conclusion, in patients with small aortic annulus and aortic stenosis, SE bioprostheses have superior hemodynamic performance but higher rates of paravalvular leak, permanent pacemaker implantation, and in-hospital stroke. BE bioprostheses were associated with a higher risk of severe prosthesis-patient mismatch.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2024.07.026 | DOI Listing |
J Invasive Cardiol
September 2025
Cardiac Surgery Unit, Mediterranea Cardiocentro, Naples, Italy.
Objectives: Failure of vascular closure device (VCD) is the most common cause of access-site vascular complications in transfemoral transcatheter aortic valve implantation (TAVI). The authors sought to determine if the systematic use of arteriotomy-site ballooning with concomitant manual compression following the delivery of a plug-based VCD (MANTA, Teleflex) can optimize toggle-plug assembly apposition to the common femoral artery (CFA) wall and improve the final hemostatic efficacy.
Methods: In this prospective, observational, single-center study, 323 consecutive patients undergoing transfemoral TAVI from October 2021 to December 2024 underwent access closure with the MANTA VCD.
Eur J Case Rep Intern Med
August 2025
Division of Internal Medicine, University Hospital of Basel, Basel, Switzerland.
Unlabelled: Encephalitis is a potentially life-threatening condition with infectious or autoimmune aetiologies. Autoimmune encephalitis includes paraneoplastic variants associated with specific onconeural antibodies such as anti-Hu, frequently linked to malignancies. Herpes simplex virus type 1 (HSV-1) is the leading infectious cause in adults.
View Article and Find Full Text PDFEur Heart J Case Rep
September 2025
Department of Cardiology, Toyohashi Heart Center, 21-1 Gobutori, Oyamacho, Toyohashi 441-8530, Japan.
Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
September 2025
Department of Cardiology, Barts Heart Center, Barts Health NHS Trust, London, UK.
Background: Degeneration of surgical bioprosthetic aortic valves is increasingly common. Redo surgical aortic valve replacement carries substantial morbidity and mortality, particularly in elderly or high-risk patients. Valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has become an established alternative, though data on the performance of self-expanding Portico and Navitor valves remain limited.
View Article and Find Full Text PDFTurk J Pediatr
September 2025
Department of Anesthesiology, All India Institute of Medical Sciences, Patna, India.
Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.
View Article and Find Full Text PDF