Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: The adoption of Robotic Pancreaticoduodenectomy (RPD) is increasing globally. Meanwhile, reduced-port RPD (RPRPD) remains uncommon, requiring robot-specific techniques not possible with laparoscopy. We introduce a unique RPRPD technique optimizing surgical field exposure.
Methods: Our RPRPD utilizes a single-site plus-two ports technique, facilitated by a single-port platform through a 5-cm incision. The configuration of robotic arms (arm1, arm2, arm3, and arm4) were strategically designed for optimal procedural efficiency, with the arms2 and arm3, alongside the assistant trocar, mounted on the single-port platform, while the arms1 and arm4 were positioned laterally across the abdomen. Drainage was established via channels created at the arm1 and arm4 insertion sites. A "gooseneck traction" was principally employed with the robotic instrument to prop up the specimen rather than grasp, improving the surgical field's visibility and access. Clinical outcomes of patients who underwent RPRPD performed between August 2020 and September 2023 by a single surgeon across two centers in Taiwan and Japan were reviewed.
Results: Fifty patients underwent RPRPD using the single-site plus-two ports technique. The gooseneck traction technique enabled goodsurgical field deployment and allowed for unrestricted movement of robotic arms with no collisions with the assistant instruments. The median operative time was 351 min (250-488 min), including 271 min (219-422 min) of console time and three minutes (2-10 min) of docking time. The median estimated blood loss was 80 mL (1-872 mL). All RPRPD procedures were successfully performed without the need for conversion to open surgery. Postoperative major morbidity (i.e., Clavien-Dindo grade ≥ IIIa) was observed in 6 (12%) patients and median postoperative hospital stay was 13 days.
Conclusions: The single-site plus-two ports RPRPD with the gooseneck traction proves to be a safe, feasible option, facilitating surgical field visibility and robotic arm maneuverability.