Exploring the biodegradability of candidate metallic intravascular stent materials using X-ray microfocus computed tomography: An in vitro study.

J Biomed Mater Res B Appl Biomater

Mechatronic, Electrical Energy and Dynamic Systems, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, Louvain-la-Neuve, Belgium.

Published: August 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In vitro testing for evaluating degradation mode and rate of candidate biodegradable metals to be used as intravascular stents is crucial before going to in vivo animal models. In this study, we show that X-ray microfocus computed tomography (microCT) presents a key added value to visualize degradation mode and to evaluate degradation rate and material surface properties in 3D and at high resolution of large regions of interest. The in vitro degradation behavior of three candidate biodegradable stent materials was evaluated: pure iron (Fe), pure zinc (Zn), and a quinary Zn alloy (ZnAgCuMnZr). These metals were compared to a reference biostable cobaltchromium (CoCr) alloy. To compare the degradation mode and degradation rate evaluated with microCT, scanning electron microscopy (SEM) and inductively-coupled plasma (ICP) were included. We confirmed that Fe degrades very slowly but with desirable uniform surface corrosion. Zn degrades faster but exhibits localized deep pitting corrosion. The Zn alloy degrades at a similar rate as the pure Zn, but more homogeneously. However, the formation of deep internal dendrites was observed. Our study provides a detailed microCT-based comparison of essential surface and corrosion properties, with a structural characterization of the corrosion behavior, of different candidate stent materials in 3D in a non-destructive way.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jbm.b.35452DOI Listing

Publication Analysis

Top Keywords

stent materials
12
degradation mode
12
x-ray microfocus
8
microfocus computed
8
computed tomography
8
candidate biodegradable
8
degradation rate
8
surface corrosion
8
degradation
6
exploring biodegradability
4

Similar Publications

Background: Long-term comparative data on drug-eluting stents (DES) and drug-coated balloons (DCB) for femoropopliteal artery (FPA) disease remain limited.

Objectives: The authors sought to compare 3-year outcomes of DES vs DCB without bailout stenting in FPA disease.

Methods: We retrospectively analyzed 1,406 patients from a multicenter registry who underwent endovascular therapy for FPA using DES (n = 342) or DCB (n = 1,064) after the successful lesion preparation.

View Article and Find Full Text PDF

Background: Previous trials have demonstrated increased 5-year risks for adverse clinical events after coronary artery implantation of poly-l-lactic acid-based bioresorbable scaffolds (BRS) compared with cobalt chromium (CoCr) everolimus-eluting stents (EES).

Objectives: The aim of this study was to evaluate the 5-year clinical outcomes of the novel sirolimus-eluting NeoVas BRS compared with CoCr EES.

Methods: A total of 560 patients with single de novo native coronary artery lesions with reference vessel diameter 2.

View Article and Find Full Text PDF

A JJ stent placed before retrograde intrarenal surgery (RIRS) may passively dilate the ureter and facilitate ureteral access sheath (UAS) implantation. No studies have examined the significance of preoperative JJ stent diameter, even though numerous studies have shown that UAS insertion is simpler in patients with them. Our study examines the relationship between preoperative ureteral stent caliber and UAS placement and RIRS results.

View Article and Find Full Text PDF

Aim        To compare the results of primary percutaneous coronary intervention (PCI) for non-ST-segment elevation acute coronary syndrome (NSTE-ACS) in patients who recently recovered from COVID-19 with those not previously infected with SARS-CoV-2; to establish prognostic criteria for PCI complications, including stent thrombosis and restenosis (ST and SR) and progression of ischemic heart disease, and to determine ways to prevent them.Material and methods         In 2021, middle-aged patients admitted to the Baku Central Clinical Hospital with a diagnosis of acute coronary syndrome who underwent urgent myocardial revascularization using percutaneous balloon angioplasty of the occluded coronary artery (CA) with implantation of a second-generation intracoronary drug-eluting stent were divided into two observation groups: the main group of 123 patients who had COVID-19 in the previous 6 months, and the control group of 112 patients who were not previously infected with SARS-CoV-2. The immediate results of PCI were assessed according to the TIMI scale; complications were assessed both clinically, by the incidence of severe complications (major adverse cardiovascular events, MACE), and angiographically, by the incidence of early and late ST and SR, and de novo stenosis that developed during the two-year observation period.

View Article and Find Full Text PDF

The TTS(through-the-scope)airway stent is a novel self-expanding nitinol alloy metal stent. Its structure and method of implantation differ significantly from those of the traditional OTW(over-the-wire)stent. In this study, we compared the mechanical properties of the TTS and OTW stents, and both of which were implanted into the tracheas of rabbits to compare the differences in complications caused by these two types of stents.

View Article and Find Full Text PDF