Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Although total knee replacement (TKR) surgery has succeeded in improving pain and deformity, a proportion of patients remain incompletely satisfied with their outcome. This prospective study aims to assess the survivorship, clinical, and radiological outcomes using a novel 'kinematic retaining' (KR) implant.

Methods: 156 patients underwent TKR surgery for primary osteoarthritis using the Physica KR implant at three European Centres. Patients were followed up for five years using both radiographic and clinical evaluations.

Results: Within 6 months post-operatively, 79.4% and 85.9% had good-excellent clinical and functional KSS values, this was maintained to 76.9% and 79.5% at five years. Mean Knee Society Score (KSS) improvement at 5 years was 32.8 (from 23 to 40) and 37.4 (from 30 to 50) (p < 0.01). All Knee Injury and Osteoarthritis Outcome Score (KOOS) sub-scores showed statistically significant improvement from before surgery at a mean of 34.7 (SD ± 16.1) to a mean of 86.6 (SD ± 16.1) at five years. The mean Oxford Knee Score (OKS) was 43.7 (±5.6), with over 80% of the patients having a good-excellent outcome at five years. OKS improved significantly by six weeks after surgery (p < 0.01) and remained constant throughout the 5-year follow-up. Visual Analogue Score (VAS) Satisfaction scores improved significantly after the post-operative time point of six weeks. From 1 year to 5 years, the average VAS was over 85 mm. The Forgotten Joint Score (FJS) increased from 64.5 at 1 year to 79.2 at 5 years after surgery (p < 0.01). No progressive adverse radiographic features were noted. Two patients were revised during the study period: one for infection and the other for aseptic loosening.

Conclusions: This novel 'kinematic retaining' knee prosthesis has shown exceptional clinical and patient-reported improvements, with a remarkable 99.4% survivorship (95.5-99.9) at five years.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11260321PMC
http://dx.doi.org/10.1016/j.jor.2024.06.023DOI Listing

Publication Analysis

Top Keywords

'kinematic retaining'
8
total knee
8
knee replacement
8
prospective study
8
tkr surgery
8
mid-term outcomes
4
outcomes 'kinematic
4
retaining' total
4
replacement multicentre
4
multicentre prospective
4

Similar Publications

Introduction: This study aimed to quantify kinematic relationships across body segments during forehand strokes to provide interpretable metrics for single-camera based lightweight table tennis diagnostics.

Methods: We analyzed 34 female players (aged 9.1-21.

View Article and Find Full Text PDF

New total knee replacement designs aim to improve patient outcomes through restoration of normal knee joint movements. This study uses in vivo fluoroscopic analysis to quantify the kinematic characteristics of the Physica KR system. Twenty-one patients underwent kinematic fluoroscopic analysis 1 year following implantation of the Physica KR knee using three defined activities (step-up, kneel, and lunge).

View Article and Find Full Text PDF

The interest in leveraging Artificial Intelligence (AI) for surgical procedures to automate analysis has witnessed a significant surge in recent years. One of the primary tools for recording surgical procedures and conducting subsequent analyses, such as performance assessment, is through videos. However, these operative videos tend to be notably lengthy compared to other fields, spanning from thirty minutes to several hours, which poses a challenge for AI models to effectively learn from them.

View Article and Find Full Text PDF

Group 2 innate lymphoid cells (ILC2s) are central effectors of type 2 immune responses in the lung; however, how mechanical cues regulate their function remains unclear. Here, we identified the mechanosensitive ion channel Piezo1 as a key regulator of ILC2 effector function through translational control. Piezo1 is highly expressed in murine and human ILC2s, and its activation by mechanical stress or the Piezo1 agonist, Yoda1 induces calcium influx, triggering mTOR signaling and selectively enhancing IL-13 protein production.

View Article and Find Full Text PDF

Statement Of Problem: Subperiosteal implants (SPIs) are considered a viable treatment option in patients with highly resorbed ridges if extensive bone grafting or other more invasive procedures are not indicated. Traditionally, SPIs were designed in a single-piece fashion, while two-piece SPIs were introduced recently. However, there are no studies in the current dental literature that compared between the two designs.

View Article and Find Full Text PDF