Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Pulsed field ablation (PFA) has become increasingly important in the treatment of cardiac arrhythmias. In addition to single-shot devices mainly used for pulmonary vein isolation, focal PFA may provide a treatment option that increases the versatility of the technique.
Objective: The purpose of this study was to provide data on feasibility, safety, and long-term outcome of focal PFA for ablation of complex atrial tachycardia (AT).
Methods: All consecutive patients (n = 34) with complex AT treated at our department between 2022 and 2023 with a focal PFA system (CENTAURI™, Galvanize Therapeutics) were included. The majority of patients (32/34) previously had undergone at least 1 radiofrequency ablation. Established contact force-sensing catheters were used for PFA application in combination with a PFA generator. Pulsed electric field trains were conducted in a R-wave triggered manner.
Results: Acute procedural success was accomplished in all patients. PFA included creation of 51 linear lesions and (re)isolation of 12 pulmonary veins. Mean procedural duration was 102.7 ± 30.3 minutes, with left atrial dwell time of 75.0 ± 24.7 minutes. Mean fluoroscopy duration was 8.7 ± 5.3 minutes. No complications occurred. After mean follow-up of 340.9 ± 130.1 days, recurrence of any AT occurred in 15 patients (44.1%). During 9 reablations, 3 gaps in previously created linear lesions were detected; the majority of recurrences (n = 6) were not related to previous PFA lesion creation.
Conclusion: Focal PFA of complex AT substrates was safe and efficient. Acute procedural success was 100%. After 1 year, the majority of patients were in sinus rhythm. A minority of recurrences was caused by insufficient PFA lesion creation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.hrthm.2024.07.024 | DOI Listing |