Correlation Between Dynamic Spray Plume and Drug Deposition of Solution-Based Pressurized Metered-Dose Inhalers.

J Aerosol Med Pulm Drug Deliv

Shanghai Sine Pharmaceutical Laboratories Co. Ltd., Shanghai, China.

Published: October 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The lack of visual dynamic spray characterization has made the understanding of the physical processes governing atomization and drug particle formation difficult. This study aimed to investigate the changes in the spray plume morphology and aerodynamic particle size of solution-based pressurized metered-dose inhalers (pMDIs) under different conditions to achieve better drug deposition. Solution-based pMDIs were studied, and the effects of various factors, such as propellant concentration, orifice diameters, and atomization chamber volume, on drug deposition were examined by analyzing the characteristics of spray plume and aerodynamic particle size. Reducing the actuator orifice and spray area led to a concentrated spray plume and increased duration and speed. Moreover, the aerodynamic particle sizes D50 and D90 decreased, whereas D10 remained relatively unchanged. Decreasing the atomization chamber volume of the actuator led to reduced spray area and an increased duration but a decreased plume velocity. D90 exhibited a decreasing trend, whereas D10 and D50 remained relatively unchanged. Reducing the propellant concentration in the prescription, the spray area and the plume velocity first decreased and then increased. The duration initially increased and then decreased. The values of D50 and D90 showed an initial decreasing followed by an increasing trend, whereas D10 remained relatively unchanged. During the development process, attention should be paid to the changes in the spray area, spray angle, duration, and speed of the spray plume. This study recommended analyzing the characteristics of the spray plume and combining the data of two or more aerodynamic particle size detection methods to verify the deposition to achieve rapid screening and obtain high lung deposition .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11502628PMC
http://dx.doi.org/10.1089/jamp.2023.0050DOI Listing

Publication Analysis

Top Keywords

spray plume
24
aerodynamic particle
16
spray area
16
spray
12
drug deposition
12
particle size
12
increased duration
12
remained unchanged
12
dynamic spray
8
plume
8

Similar Publications

Conventional pressurized metered dose inhalers (pMDIs) often face challenges in efficiently delivering therapeutic aerosols for the treatment of pulmonary diseases. This study proposes a novel design enhancement: the integration of a grid screen at the outlet of a standard pMDI actuator, supported by a slender 0.8 mm wire.

View Article and Find Full Text PDF

A Review of Multiscale Interaction Mechanisms of Wind-Leaf-Droplet Systems in Orchard Spraying.

Sensors (Basel)

July 2025

Science Innovation Center, Chinese Academy of Agriculture Mechanization Sciences Group Co., Ltd., Beijing 100083, China.

The multiscale interactive system composed of wind, leaves, and droplets serves as a critical dynamic unit in precision orchard spraying. Its coupling mechanisms fundamentally influence pesticide transport pathways, deposition patterns, and drift behavior within crop canopies, forming the foundational basis for achieving intelligent and site-specific spraying operations. This review systematically examines the synergistic dynamics across three hierarchical scales: Droplet-leaf surface wetting and adhesion at the microscale; leaf cluster motion responses at the mesoscale; and the modulation of airflow and spray plume diffusion by canopy architecture at the macroscale.

View Article and Find Full Text PDF

The reformulation of suspension-based pressurized metered dose inhalers (pMDI) with low global warming potential (GWP) propellants is challenged by wide-ranging changes to their chemicophysical properties such as vapor pressure, density and latent heat. The effect of low-GWP propellants on spray pattern and plume geometry for suspension pMDIs are not fully understood. There is a lack of data regarding the role of propellant choice and potential interactions with suspended drugs, which may explain performance variations between products and guide development of in-silico models.

View Article and Find Full Text PDF

In electrospray ionization (ESI) mass spectrometry (MS), an electric DC potential is often applied to a metal capillary used to infuse a liquid sample. However, in some cases, especially when employing nanoelectrospray ionization (nanoESI), it is convenient to use a nonconducting capillary for sample delivery and spraying. In these cases, the potentials can be applied, for example, using a metal union placed in the proximity of the capillary outlet or to an electrode located in the sample reservoir near the capillary inlet.

View Article and Find Full Text PDF

Novel branched copolymer surfactants (BCS) allow the formation of oil-in-water emulsions that exhibit a temperature-induced liquid-to-gel transition. If the temperature of this transition is between room and body temperature (ca 25 and 37 °C, respectively), then the emulsions form a gel in situ upon contact with the body. A major advantage of this in situ gelation is the potential to manipulate the materials at room temperature in the low viscosity liquid state, then administer them to the body to initiate a switch to a retentive gel state, which could be used to deliver drugs to challenging sites such as the nasal mucosa.

View Article and Find Full Text PDF