98%
921
2 minutes
20
The corrosion inhibition of ( )- , -bis(4-(dimethylamino)benzylidene)-ethane-1,2-diamine, DMAB, against the destruction of C-steel in dilute HCl media (1.0 M) was examined. The techniques of gravimetry, gasometry, potentiodynamic, and electrochemical impedance spectroscopy are utilized. The rate of corrosion is found to decrease with more additions of the DMAB compound. The inhibition efficacy increases with concentrations to reach 97.7% at 5.0 mM and 298 K. The protection of metal destruction is controlled by the adsorption of the DMAB molecules on the metallic surface obeying Langmuir's pattern. The computed Δ° values are characterized by negative sign, explaining the spontaneity of the adsorption process. These values vary between -38.70 and -35.13 kJ mol depending on the temperature, which proves the physio- and chemisorption mechanisms. The reduction in values with can be attributed to the desorption of some DMAB molecules from the electrode surface. Theoretical quantum computation confirms the adsorption of the DMAB compound in concurrence with the data obtained by practical techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11238229 | PMC |
http://dx.doi.org/10.1021/acsomega.4c03135 | DOI Listing |
Anal Chem
May 2025
State Key Laboratory of Bioelectronics, Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, China.
Monoamine oxidase B (MAO-B) and acetylcholinesterase (AChE) are potential biomarkers for Alzheimer's disease (AD). However, few methods exist to detect both AChE and MAO-B simultaneously. In this study, we developed a SERS sensor for the simultaneous detection of AChE and MAO-B based on the one-pot reaction system, which provided more valuable information for early AD diagnosis.
View Article and Find Full Text PDFTalanta
January 2025
Aix Marseille Univ, LCE, Marseille, France. Electronic address:
A new method is described for acetone (C(CH)O) determination in water samples. The method is based on the reaction with 4-(dimethylamino)benzaldehyde (DMAB) in dimethyl sulfoxide (DMSO) in slightly basic medium, resulting in a highly fluorescent compound with fluorescent wavelengths undisturbed by other common fluorescent compounds. Experimental conditions were optimized (reagents concentrations, reaction time) to reach optimal sensitivity.
View Article and Find Full Text PDFAnal Chim Acta
August 2024
Department of Atomic and Molecular Physics, Manipal Academy of Higher Education, Manipal, 576104, India; Center for Applied Nanosciences (CAN), Manipal Academy of Higher Education, Manipal, 576104, India. Electronic address:
Background: Precise localized printing of plasmonic nanoparticles at desired locations can find a plethora of applications in diverse areas, including nanophotonics, nanomedicine, and microelectronics. The focused laser beam-assisted optical printing technique has illustrated its potential for the localized printing of differently shaped plasmonic particles. However, the technique is either time-consuming or often requires focused optical radiation, limiting its practical applications.
View Article and Find Full Text PDFACS Omega
July 2024
Faculty College of Umluj, Umluj, University of Tabuk, Tabuk 47713, Saudi Arabia.
The corrosion inhibition of ( )- , -bis(4-(dimethylamino)benzylidene)-ethane-1,2-diamine, DMAB, against the destruction of C-steel in dilute HCl media (1.0 M) was examined. The techniques of gravimetry, gasometry, potentiodynamic, and electrochemical impedance spectroscopy are utilized.
View Article and Find Full Text PDFProg Orthod
June 2024
Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Plattenstrasse 11, Zurich, 8032, Switzerland.
Background: The aim of the present study was to investigate qualitatively and quantitatively the elution of substances from polyester-urethane (Invisalign™) aligners and resin composite attachments (Tetric EvoFlow) in vivo.
Methods: Patients (n = 11) treated with the aligners and attachments (16 per patient, without other composite restorations) for an average of 20 months, who were planned for attachment removed were enrolled in the study. Patients were instructed to rinse with 50 mL of distilled water upon entry and the rinsing solution was collected (before removal).