98%
921
2 minutes
20
Multimodal medical image fusion is a perennially prominent research topic that can obtain informative medical images and aid radiologists in diagnosing and treating disease more effectively. However, the recent state-of-the-art methods extract and fuse features by subjectively defining constraints, which easily distort the exclusive information of source images. To overcome these problems and get a better fusion method, this study proposes a 2D data fusion method that uses salient structure extraction (SSE) and a swift algorithm via normalized convolution to fuse different types of medical images. First, salient structure extraction (SSE) is used to attenuate the effect of noise and irrelevant data in the source images by preserving the significant structures. The salient structure extraction is performed to ensure that the pixels with a higher gradient magnitude impact the choices of their neighbors and further provide a way to restore the sharply altered pixels to their neighbors. In addition, a Swift algorithm is used to overcome the excessive pixel values and modify the contrast of the source images. Furthermore, the method proposes an efficient method for performing edge-preserving filtering using normalized convolution. In the end,the fused image are obtained through linear combination of the processed image and the input images based on the properties of the filters. A quantitative function composed of structural loss and region mutual data loss is designed to produce restrictions for preserving data at feature level and the structural level. Extensive experiments on CT-MRI images demonstrate that the proposed algorithm exhibits superior performance when compared to some of the state-of-the-art methods in terms of providing detailed information, edge contour, and overall contrasts.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11244787 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0301441 | PLOS |
Retina
September 2025
From the Vitreous, Retina, Macula Consultants of New York, New York, NY.
Purpose: To reassess the anatomic basis of optic disc pit maculopathy (OPM) using swept-source optical coherence tomography (SS-OCT) and to characterize the broader structural abnormalities comprising the optic pit complex.
Methods: Sixteen patients with OPM were imaged using a high-resolution SS-OCT system (DREAM OCT). Cross-sectional and volume-rendered scans were analyzed for lamina cribrosa defects, intraneural cavitations, and pathways for fluid entry into or beneath the retina.
Retina
September 2025
Harvard Retinal Imaging Lab, Massachusetts Eye and Ear, Boston, MA, USA.
Purpose: To investigate associations among expanded field swept-source optical coherence tomography angiography (SS-OCTA) biomarkers and the development of tractional retinal detachment (TRD) in patients with proliferative diabetic retinopathy (PDR).
Methods: Patients with PDR without TRD at baseline were imaged with SS-OCTA. Quantitative and qualitative OCTA metrics were independently evaluated by two trained graders.
Unlabelled: Passive Acoustic Mapping (PAM) is rapidly emerging as a ubiquitous tool for real-time localization and monitoring of therapeutic ultrasound treatments involving cavitation in the context of safety or efficacy. The ability of PAM to spatially quantify and resolve cavitation activity offers a unique opportunity to correlate the energy of cavitation phenomena with locally observed bioeffects.
Objective: We aim to develop methods of measuring and reporting spatio-temporally varying cavitation energies that are energy-preserving, device-independent, and adequately normalized to the volume of tissue being affected by the reported cavitation activity.
Biol Trace Elem Res
September 2025
Department of Environmental Sciences, Faculty of Biological Sciences, Kohat University of Science and Technology Kohat, Khyber Pakhtunkhwa, 26000, Pakistan.
The aim of the study was to evaluate the toxic metals (TMs) pollution, bioaccumulation and its potential health risk via consumption of different vegetables irrigated by different water sources released from industrial estates of Khyber Pakhtunkhwa. Water (fresh and waste), soil and vegetables samples were collected in triplicates and acid digested. Digestion of samples were followed by evaporation and filtration and then assessed for TMs via atomic absorption spectrophotometer.
View Article and Find Full Text PDFInt J Legal Med
September 2025
University Center of Legal Medicine Lausanne-Geneva, University of Geneva, Geneva University Hospitals, Rue Michel-Servet 1, 1211, Geneva 4, Switzerland.
In the past 10 years, the Multi-phase Post-mortem Computed Tomography Angiography (MPMCTA) has considerably improved the quality and precision of postmortem diagnoses, particularly in cases with vascular implication. MPMCTA is known to have higher sensitivity for detecting the source of a hemorrhage than autopsy. Death by upper gastro-intestinal (GI) bleeding is not so uncommon in forensic practice.
View Article and Find Full Text PDF