A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Photon-counting detector CT with an ultra-low-dose contrast media to diagnose a renal pseudoaneurysm: A case report. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A 75-year-old male, weighing 71 kg, was admitted to our institution with anemia related to a subcapsular hematoma after accidental extraction of a nephrostomy catheter. While the patient exhibited the progression of chronic kidney disease, he was not yet on dialysis. His serum creatinine level increased to 6.8 mg/dL, with an estimated glomerular filtration rate of 7.4 mL/min/1.73 m. Radiologists planned contrast-enhanced photon-counting detector CT (PCD-CT) with an ultra-low-dose contrast media to mitigate the impact on renal function. The contrast media dosage was set at 7.4 gI, which was 82.6% lower that used in the standard protocol for a male weighing 71 kg. Non-contrast-enhanced PCD-CT identified a low-density nodular area within the renal subcapsular hematoma. Contrast-enhanced PCD-CT revealed contrast enhancement in both the early and late phases corresponding to the nodular area. On virtual monoenergetic images, the renal pseudoaneurysm was most clearly delineated at 40 keV. Following the diagnosis of a pseudoaneurysm, transcatheter arterial coil embolization was performed. No subsequent progression of anemia or the deterioration of renal function was observed, showcasing the potential of ultra-low-dose contrast-enhanced PCD-CT for the detection of small vascular abnormalities while minimizing adverse effects on renal function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11228645PMC
http://dx.doi.org/10.1016/j.radcr.2024.05.077DOI Listing

Publication Analysis

Top Keywords

contrast media
12
renal function
12
photon-counting detector
8
ultra-low-dose contrast
8
renal pseudoaneurysm
8
male weighing
8
subcapsular hematoma
8
nodular area
8
contrast-enhanced pcd-ct
8
renal
6

Similar Publications