A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Performance of Microsoft Azure Kinect DK as a tool for estimating human body segment lengths. | LitMetric

Performance of Microsoft Azure Kinect DK as a tool for estimating human body segment lengths.

Sci Rep

Department of Diagnostic Radiology, Chang Gung Memorial Hospital, No. 8, Section West, Jiapu Road, Puzi City, Chiayi, 613016, Taiwan.

Published: July 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The Microsoft Kinect depth sensor, with its built-in software that automatically captures joint coordinates without markers, could be a potential tool for ergonomic studies. This study investigates the performance of Kinect in limb segment lengths using dual-energy X-ray absorptiometry (DXA) as a reference. Healthy children and adults (n = 76) were recruited for limb length measurements by Kinect and DXA. The results showed consistent ratios of arm, forearm, thigh, and leg lengths to height, which were 0.16, 0.14, 0.23, and 0.22 respectively, for both age groups and methods. Kinect exhibited perfect correlation among all limb lengths, indicating fixed proportions assumed by its algorithm. Comparing the two methods, there was a strong correlation (R = 0.850-0.985) and good to excellent agreement (ICC = 0.829-0.977), except for the right leg in adults, where agreement was slightly lower but still moderate (ICC = 0.712). The measurement bias between the methods ranged from - 1.455 to 0.536 cm. In conclusion, Kinect yields outcomes similar to DXA, indicating its potential utility as a tool for ergonomic studies. However, the built-in algorithm of Kinect assumes fixed limb proportions for individuals, which may not be ideal for studies focusing on investigating limb discrepancies or anatomical differences.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11233572PMC
http://dx.doi.org/10.1038/s41598-024-66798-0DOI Listing

Publication Analysis

Top Keywords

segment lengths
8
tool ergonomic
8
ergonomic studies
8
kinect
7
limb
5
performance microsoft
4
microsoft azure
4
azure kinect
4
kinect tool
4
tool estimating
4

Similar Publications