Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Detrusor underactivity (DU) is a common cause of lower urinary tract symptoms (LUTS). To date, no consensus has been reached on the urodynamic criteria for defining DU. We previously proposed the area under the curve of the Watts factor (WF-AUC) as a new parameter for diagnosing DU. By comparing previously reported five criteria for DU and WF-AUC, we analyzed whether the WF-AUC could assess detrusor contraction in women with LUTS.

Methods: Using urodynamic data of consecutive 77 women with LUTS, first, we classified DU based on previously reported five criteria. Second, we assessed the potential correlation between multiple parameters and WF-AUC. Third, receiver operating characteristic curve analysis was performed to determine the cutoff value of WF-AUC for diagnosing DU based on previously reported five criteria. Fourth, a linear regression analysis was conducted and compared using multiple criteria and female bladder outlet obstruction index (BOOIf).

Results: WF-AUC was positively correlated with the maximum values of WF, bladder contractility index (BCI), and projected isovolumetric pressure 1 (PIP1) with correlation coefficients of 0.63, 0.57, and 0.34, respectively. AUC for diagnosing DU based on previously reported five criteria ranging from 0.773 to 0.896 with different cutoff values of AUC-WF. The Spearman's correlation test revealed that BOOIf was significantly correlated with BCI, but not W, PIP1 and WF-AUC.

Conclusions: This study demonstrated the non-inferiority of the WF-AUC compared to previously reported criteria for defining DU. Depending on the cutoff value, the WF-AUC could appropriately evaluate women with DU, regardless of the presence of BOO.

Download full-text PDF

Source
http://dx.doi.org/10.1111/iju.15531DOI Listing

Publication Analysis

Top Keywords

reported criteria
20
based reported
12
watts factor
8
parameter diagnosing
8
detrusor underactivity
8
criteria defining
8
wf-auc
8
cutoff wf-auc
8
diagnosing based
8
criteria
7

Similar Publications

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

Background: Recent advances in high-throughput sequencing technologies have enabled the collection and sharing of a massive amount of omics data, along with its associated metadata-descriptive information that contextualizes the data, including phenotypic traits and experimental design. Enhancing metadata availability is critical to ensure data reusability and reproducibility and to facilitate novel biomedical discoveries through effective data reuse. Yet, incomplete metadata accompanying public omics data may hinder reproducibility and reusability and limit secondary analyses.

View Article and Find Full Text PDF

Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.

View Article and Find Full Text PDF

Background: Idiopathic normal pressure hydrocephalus (iNPH) predominantly manifests with gait disturbances, yet clinical assessments are vulnerable to confirmation bias, particularly post-shunt surgery. Blinded video evaluations are a method to enhance objectivity in gait assessment, but their reliability has never been systematically investigated. The aim was to evaluate the inter-rater reliability of blinded gait assessments in iNPH patients and to investigate how these assessments correlate with the Hellström iNPH scale and patient-reported health status following shunt surgery.

View Article and Find Full Text PDF

Background: The benefits of physical activity for frail older acutely hospitalized adults are becoming increasingly clear. To enhance opportunities for physical activity on geriatric wards, it is essential to understand the older adult's perspective.

Aim: The aim of the study was to explore the experiences and perceptions of physical activity among older adults during hospital stays on a geriatric ward.

View Article and Find Full Text PDF