98%
921
2 minutes
20
Objectives: To assess navigation accuracy for complete-arch implant placement with immediate loading of digitally prefabricated provisional.
Materials And Methods: Consecutive edentulous and terminal dentition patients requiring at least one complete-arch FDP were treated between December 2020 and January 2022. Accuracy was evaluated by superimposing pre-operative and post-operative cone beam computed tomography (CBCT), recording linear (mm) and angular (degrees) deviations. T-tests were performed to investigate the potential effect of the registration algorithm (fiducial-based vs. fiducial-free), type of references for the fiducial-free algorithm (teeth vs. bone screws), site characteristic (healed vs. post-extractive), implant angulation (axial vs. tilted), type of arch (maxilla vs. mandible) on the accuracy with p-value <0.05.
Results: Twenty-five patients, 36 complete-arches, and 161 implants were placed. The overall mean angular deviation was 2.19° (SD 1.26°). The global platform and apex mean deviations were 1.17 mm (SD 0.57 mm), and 1.30 mm (SD 0.62 mm). Meaningful global platform (p = 0.0009) and apical (p = 0.0109) deviations were experienced only between healed and post-extraction sites. None of the analyzed variables significantly influenced angular deviation. Minor single-axis deviations were reported for the type of jaw (y-axis at implant platform and apex), registration algorithm (y-axis platform and z-axis deviations), and type of references for the fiducial-free algorithm. No statistically significant differences were found in relation to implant angulation.
Conclusions: Within the study limitations navigation was reliable for complete-arch implant placement with immediate loading digitally pre-fabricated FDP. AI-driven surface anatomy identification and calibration protocol made fiducial-free registration as accurate as fiducial-based, teeth and bone screws equal as references. Implant site characteristics were the only statistically significant variable with healed sites reporting higher accuracy compared to post-extractive. Live-tracked navigation surgery enhanced operator performance and accuracy regardless of implant angulation and type of jaw. A mean safety room of about 1 mm and 2° should be considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/cid.13360 | DOI Listing |
JMIR Res Protoc
September 2025
Department of Food Science and Technology, Kaunas University of Technology, Kaunas, Lithuania.
Background: Fermented foods vary significantly by food substrate and regional consumption patterns. Although they are consumed worldwide, their intake and potential health benefits remain understudied. Europe, in particular, lacks specific consumption recommendations for most fermented foods.
View Article and Find Full Text PDFBull Entomol Res
September 2025
Instituto de Biotecnología y Ecología Aplicada, Universidad Veracruzana, Xalapa, Veracruz, México.
Insect pupae change morphologically (e.g., pigmentation of eyes, wings, setae and legs) during the intrapuparial period.
View Article and Find Full Text PDFACS Chem Neurosci
September 2025
Chemical and Biomolecular Engineering Dept, University of California, Los Angeles, Los Angeles, California 90095, United States.
Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .
View Article and Find Full Text PDFJ Ultrasound Med
September 2025
Department of Clinical Analysis, Federal University of Santa Catarina (UFSC), Florianópolis, Brazil.
Objectives: To evaluate the performance of artificial intelligence (AI)-based models in predicting elevated neonatal insulin levels through fetal hepatic echotexture analysis.
Methods: This diagnostic accuracy study analyzed ultrasound images of fetal livers from pregnancies between 37 and 42 weeks, including cases with and without gestational diabetes mellitus (GDM). Images were stored in Digital Imaging and Communications in Medicine (DICOM) format, annotated by experts, and converted to segmented masks after quality checks.
Multimed Man Cardiothorac Surg
September 2025
Department of Thoracic Surgery, New Cross Hospital, Royal Wolverhampton NHS Trust, Wolverhampton, UK
Three-dimensional (3D) guided robotic-assisted thoracic surgery is increasingly recognized as the pioneering approach for the most complex of pulmonary resections, offering high-definition 3D visualization, enhanced instrument augmentation and tremor-free tissue articulation. Compared with open thoracotomy, the robotic platform is associated with reduced peri-operative morbidity, shorter hospital admissions and faster patient recovery. However, sublobar resections such as segmentectomies remain anatomically and technically demanding, particularly in the context of resecting multiple segments, as showcased in this right S1 and S2 segmentectomy.
View Article and Find Full Text PDF