Noninvasive Pressure-Volume Loops Predict Major Adverse Cardiac Events in Heart Failure With Reduced Ejection Fraction.

JACC Adv

Department of Clinical Sciences Lund, Clinical Physiology, Skåne University Hospital, Lund University, Lund, Sweden.

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Heart failure with reduced ejection fraction (HFrEF) is characterized by ventricular remodeling and impaired myocardial energetics. Left ventricular pressure-volume (PV) loop analysis can be performed noninvasively using cardiovascular magnetic resonance (CMR) imaging to assess cardiac thermodynamic efficiency.

Objectives: The aim of the study was to investigate whether noninvasive PV loop parameters, derived from CMR, could predict major adverse cardiac events (MACE) in HFrEF patients.

Methods: PV loop parameters (stroke work, ventricular efficiency, external power, contractility, and energy per ejected volume) were computed from CMR cine images and brachial blood pressure. The primary end point was MACE (cardiovascular death, heart failure (HF) hospitalization, myocardial infarction, revascularization, ventricular tachycardia/fibrillation, heart transplantation, or left ventricular assist device implantation within 5 years). Associations between PV loop parameters and MACE were evaluated using multivariable Cox regression.

Results: One hundred and sixty-four HFrEF patients (left ventricular ejection fraction ≤40%, age 63 [IQR: 55-70] years, 79% male) who underwent clinical CMR examination between 2004 and 2014 were included. Eighty-eight patients (54%) experienced at least one MACE after an average of 2.8 years. Unadjusted models demonstrated a significant association between MACE and all PV loop parameters ( < 0.05 for all), HF etiology ( < 0.001), left ventricular ejection fraction ( = 0.003), global longitudinal strain ( < 0.001), and N-terminal prohormone of brain natriuretic peptide level ( = 0.001). In the multivariable Cox regression analysis adjusted for age, sex, hypertension, diabetes, and HF etiology, ventricular efficiency was associated with MACE (HR: 1.04 (95% CI: 1.01-1.08) per-% decrease,  = 0.01).

Conclusions: Ventricular efficiency, derived from noninvasive PV loop analysis from standard CMR scans, is associated with MACE in patients with HFrEF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11198266PMC
http://dx.doi.org/10.1016/j.jacadv.2024.100946DOI Listing

Publication Analysis

Top Keywords

loop parameters
16
left ventricular
12
predict major
8
major adverse
8
adverse cardiac
8
cardiac events
8
heart failure
8
ventricular
6
loop
5
mace
5

Similar Publications

Purpose: To report clinical outcomes in patients implanted with an isofocal optic-design intraocular lens (IOL) with double C-loop haptics following cataract surgery.

Methods: This was a multicentre-prospective-study involving 108 eyes (54 subjects) implanted with the Isopure Serenity (BVI, Inc). IOL.

View Article and Find Full Text PDF

Objective: The study utilized non-invasive myocardial work indices to investigate myocardial injury in infants born to mothers with severe preeclampsia (SPE) and to explore the duration of this myocardial damage during the neonatal period.

Methods: This prospective study included 34 preterm infants born to mothers with SPE and 28 preterm infants born to mothers without severe pregnancy complications (termed "controls"). Echocardiography was performed in infants within 24 h of birth, then again at 48-72 h and 14-28 days, to obtain echocardiographic parameters.

View Article and Find Full Text PDF

New Cyclic Lipopeptide Compounds for Efficiently Inhibiting Cellular Inflammation and Collagen-Induced Arthritis in Mice.

J Med Chem

September 2025

Department of Biotherapy, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, No.17, Third Section of Renmin South Road, Chengdu 610041, China.

Rheumatoid arthritis (RA) is a systemic autoimmune disease, and a large number of patients do not respond well to existing treatment strategies. Our previous report has discovered that the cyclic lipopeptide (CLP) daptomycin (DAP) has a good suppressive arthritis activity in mice. In this study, we have designed and synthesized five novel DAP-derived CLPs by structural optimization on the loop of DAP and further studied their anti-RA effects in vitro and in vivo.

View Article and Find Full Text PDF

Terminal Harvest Procedure of a Large Animal Model of Chronic Myocardial Ischemia with Hemodynamic Characterization and Perfusion Analysis.

J Vis Exp

August 2025

Department of Surgery, Division of Cardiothoracic Surgery, Warren Alpert Medical School, Brown University; Cardiovascular Research Center, Rhode Island Hospital.

Reproducibility and research integrity are foundational tenets to scientific discovery, which are produced utilizing well-established, proven principles and protocols. Furthermore, with the ever-increasing prevalence and burden cardiovascular disease (CVD) places on individuals and society at large, it deems essential to cultivate robust and validated model for investigation. Our group utilizes a two-surgery protocol in a swine model that has been progressively refined over the last twenty years, in which we first induce chronic myocardial ischemia by placement of an ameroid constrictor mimicking the pathophysiology of coronary artery disease (CAD) in humans.

View Article and Find Full Text PDF

Raman-based PAT for multi-attribute monitoring during VLP recovery by dual-stage CFF: attribute-specific spectral preprocessing for model transfer.

Front Bioeng Biotechnol

August 2025

Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.

Spectroscopic soft sensors are developed by combining spectral data with chemometric modeling, and offer as Process Analytical Technology (PAT) tools powerful insights into biopharmaceutical processing. In this study, soft sensors based on Raman spectroscopy and linear or partial least squares (PLS) regression were developed and successfully transferred to a filtration-based recovery step of precipitated virus-like particles (VLPs). For near real-time monitoring of product accumulation and precipitant depletion, the dual-stage cross-flow filtration (CFF) set-up was equipped with an on-line loop in the second membrane stage.

View Article and Find Full Text PDF