Introduction: Elbow dislocations, particularly those associated with varus posteromedial rotary instability, are relatively uncommon. We present the case of a 25-year-old male initially managed nonoperatively for a posterior elbow dislocation, who subsequently experienced irreducible re-dislocation with characteristic fractures of the anteromedial facet and tip of the coronoid, indicative of varus posteromedial rotary instability.

Case Report: Following an unsuccessful attempt at closed reduction under general anesthesia, open reduction was performed, revealing the interposition of the posterior capsule of the humero-ulnar joint as the cause of irreducibility. Fixation of the coronoid fracture was undertaken, and the patient exhibited excellent functional outcomes at a 4.5-year follow-up.

Conclusion: This case underscores the rarity of irreducible elbow dislocation in the context of varus posteromedial rotary instability and highlights the crucial role of capsular interposition in such cases. Successful open reduction, coronoid fixation, and attentive postoperative care contributed to the patient's favorable long-term functional outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11189095PMC
http://dx.doi.org/10.13107/jocr.2024.v14.i06.4502DOI Listing

Publication Analysis

Top Keywords

varus posteromedial
16
posteromedial rotary
16
elbow dislocation
12
rotary instability
12
posterior elbow
8
open reduction
8
irreducible complex
4
complex posterior
4
elbow
4
varus
4

Similar Publications

Early failure of tibial implants following unicompartmental knee arthroplasty might result from a decrease in bone mineral density in the medial tibial plateau. This study quantitatively assessed this bone mineral density decrease caused by tibial overresection during medial unicompartmental knee arthroplasty, using Hounsfield units, and investigated factors influencing significant reductions in Hounsfield units in 40 knees (34 patients) before surgery. A three-dimensional tibial model was reconstructed from computed tomography scans, and mean Hounsfield units of the central, anterior, anteromedial, medial, posteromedial, and posterior regions of the medial tibial plateau were extracted in 2-mm-thick layers at depth of 4, 6, and 8 mm beneath the articular surface.

View Article and Find Full Text PDF

Anteromedial Coronoid Facet Fractures with Associated Injuries have Inferior Outcomes to Isolated Fractures: A Clinical Outcomes Comparison.

J Shoulder Elbow Surg

August 2025

Faculty of Medicine and Dentistry Surgery Department, University of Alberta, Edmonton, AB, Canada; Western Hand & Upper Limb Facility, Sturgeon Hospital, Edmonton, AB, Canada.

Background: Varus posteromedial rotatory instability typically results in an isolated anteromedial coronoid (AMC) fracture without an associated radial head fracture or elbow dislocation. However, recent series have shown concomitant radial head fractures and elbow dislocations may be seen in association with AMC fractures in other injury patterns with an unclear effect on patient outcomes. Therefore, our objective was to compare postoperative patient outcomes in AMC fractures with and without concomitant radial head fractures or elbow dislocations.

View Article and Find Full Text PDF

Purpose: Severe varus knee osteoarthritis (OA) alters weight-bearing mechanics, leading to progressive stress concentration on the posteromedial tibial plateau. In select cases, this results in the development of a Posteromedial Varus Fatigue Fragment (PVFF), a chronic stress-related fracture that remains ununited and influences knee stability, surgical planning, and implant selection. This study aims to evaluate the incidence, radiographic detectability, and intraoperative significance of PVFF in patients undergoing total knee arthroplasty (TKA).

View Article and Find Full Text PDF

Purpose: Kinematic alignment (KA) and imageless computer-assisted surgery in total knee arthroplasty (TKA) typically compensate for cartilage wear by applying a standard 2-mm adjustment. However, recent concerns have emerged regarding the accuracy of this assumption. This study aimed to assess, for the first time in vivo, the femoral cartilage thickness on the unworn side in a consecutive series of TKA patients.

View Article and Find Full Text PDF