A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Rationalizing polyp matching criteria in colon capsule endoscopy: an international expert consensus through RAND (modified DELPHI) process. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Colon capsule endoscopy (CCE) has gained momentum as an alternative modality for the investigation of the lower gastrointestinal tract. Of the few challenges that remain, the comparison and - eventually - matching of polyps at different timestamps leads to the potential for double reporting and can contribute to false-positive findings and inaccuracies. With the impending artificial intelligence integration, the risk of double reporting the same polyp due to the lack of information on spatial orientation underscores the necessity for establishing criteria for polyp matching.

Objectives: This RAND/University of California, Los Angeles (modified Delphi) process aims to identify the key factors or components used to match polyps within a CCE video. This involves exploring the attributes of each factor to create comprehensive polyp-matching criteria based on international expert consensus.

Design: A systematic qualitative study using surveys.

Methods: A panel of 11 international CCE experts convened to assess a survey comprised of 60 statements. Participants anonymously rated statement appropriateness on a 1-9 scale (1-3: inappropriate, 4-6: uncertain and 7-9: appropriate). Following a virtual group discussion of the Round 1 results, a Round 2 survey was developed and completed before the final analysis.

Results: The factors that were agreed to be essential for polyp matching include (1) timestamp, (2) polyp localization, (3) polyp vascular pattern, (4) polyp size, (5) time interval of the polyp appearance between the green and yellow camera, (6) surrounding tissue, (7) polyp morphology and (8) polyp surface and contour. When five or more factors are satisfied, it was agreed that the comparing polyps are likely the same polyp.

Conclusion: This study has established the first complete criteria for polyp matching in CCE. While it might not provide a definitive solution for matching difficult, small and common polyps, these criteria serve as a framework to guide and facilitate the process of polyp-matching.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11179528PMC
http://dx.doi.org/10.1177/17562848241242681DOI Listing

Publication Analysis

Top Keywords

polyp matching
12
polyp
10
colon capsule
8
capsule endoscopy
8
international expert
8
modified delphi
8
delphi process
8
double reporting
8
criteria polyp
8
matching
5

Similar Publications