Voice reduction in cardiac auscultation sounds with reference signals measured from vocal resonators.

J Acoust Soc Am

Department of Biomedical Engineering, College of Medicine and Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul 03080, Republic of Korea.

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study proposes the use of vocal resonators to enhance cardiac auscultation signals and evaluates their performance for voice-noise suppression. Data were collected using two electronic stethoscopes while each study subject was talking. One collected auscultation signal from the chest while the other collected voice signals from one of the three voice resonators (cheek, back of the neck, and shoulder). The spectral subtraction method was applied to the signals. Both objective and subjective metrics were used to evaluate the quality of enhanced signals and to investigate the most effective vocal resonator for noise suppression. Our preliminary findings showed a significant improvement after enhancement and demonstrated the efficacy of vocal resonators. A listening survey was conducted with thirteen physicians to evaluate the quality of enhanced signals, and they have received significantly better scores regarding the sound quality than their original signals. The shoulder resonator group demonstrated significantly better sound quality than the cheek group when reducing voice sound in cardiac auscultation signals. The suggested method has the potential to be used for the development of an electronic stethoscope with a robust noise removal function. Significant clinical benefits are expected from the expedited preliminary diagnostic procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1121/10.0026237DOI Listing

Publication Analysis

Top Keywords

cardiac auscultation
12
vocal resonators
12
signals
8
auscultation signals
8
evaluate quality
8
quality enhanced
8
enhanced signals
8
sound quality
8
voice
4
voice reduction
4

Similar Publications

Background: Primary care providers (PCPs) are not successful in accurately identifying Still's murmur with no available clinical tools to aid in the process. Existing deep learning (DL) methods primaryly focused on adult pathological murmurs or murmur detection, lacking dedicated approaches for Still's murmur. Furthermore, the absence of a specialized database hampers the development and validation of AI models for pediatric populations.

View Article and Find Full Text PDF

Background: Common cocaine-induced arrhythmias include tachyarrhythmias such as sinus tachycardia, supraventricular tachycardia, and atrial fibrillation. Most studies evaluating cocaine toxicosis in canines have been performed in an experimental setting, using intravenous administration of the drug. Though helpful, these studies cannot be directly extrapolated in a clinical setting given the different routes of administration.

View Article and Find Full Text PDF

Continuous cardiovascular monitoring is essential for the early detection of cardiac events, but conventional electrode-based ECG systems cause skin irritation and are unsuitable for long-term wear. We propose an electrode-free ECG monitoring approach that leverages synchronized phonocardiogram (PCG) and seismocardiogram (SCG) signals captured by wireless mechano-acoustic sensors. PCG provides precise valvular event timings, while SCG provides mechanical context, enabling the robust identification of systolic/diastolic intervals and pathological patterns.

View Article and Find Full Text PDF

Elevated peak blood pressure (BP) during exercise is an independent risk factor for future hypertension, but the mechanisms responsible for inter-individual differences in exercise BP remain poorly studied. Forty-four participants (22±5 years; 18 female) completed a maximal exercise test (modified Bruce protocol) with brachial artery BP measured every 90-seconds (automated auscultation). On a subsequent visit, participants underwent measures of carotid-femoral pulse wave velocity (n=37), superficial femoral artery flow-mediated dilation (n=27), and muscle sympathetic nerve activity (MSNA; microneurography, n=44).

View Article and Find Full Text PDF

Machine learning-based CAD detection using integrated ECG and PCG parameter features.

Biomed Phys Eng Express

September 2025

State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, People's Republic of China.

The combined analysis of electrocardiogram (ECG) and phonocardiogram signals(PCG) has demonstrated significant potential in the non-invasive detection of coronary artery disease (CAD). The efficacy of combining cardiac pathological parameters such as electromechanical delay (EMD), left ventricular ejection time (LVET), pre-ejection period (PEP), and the cardiac dysfunction index (SDI score) for the intelligent diagnosis of CAD remains unverified. In this study, an improved Pan-Tompkins algorithm was employed to locate the QRS complexes in the ECG signal accurately.

View Article and Find Full Text PDF