98%
921
2 minutes
20
Objectives: To evaluate the diagnostic performance of different brands of immunochromatographic test (ICT) reagents for using homogenized samples to provide a reference for reagent quality control.
Methods: Eight commercially available ICT reagents were evaluated, of which three used the latex method and five used the colloidal gold method. Analytical performance evaluation using a pure culture broth of , as well as clinical application validation using cervical epithelial cell samples acquired from the research subjects, were conducted. The concentration of was quantified using a nucleic acid amplification test.
Results: The limit of detection (LOD) of different ICT reagents in the analytical performance evaluation varied from 9.5 × 10 to 1 × 10 IFU/mL, and only one reagent met the LOD specified in the manufacturer's instructions. Likewise, only one reagent in the clinical application validation achieved the analytical LOD, four reagents were 2.1-4.2-fold of the analytical LODs, and three reagents failed to detect positive results in clinical samples.
Conclusions: The diagnostic performance of different methods and different brands of ICT reagents in clinical practice was different from the manufacturer's instructions and the results of laboratory evaluation. The diagnostic performance of reagents should be evaluated before they are actually used in clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11167380 | PMC |
http://dx.doi.org/10.1016/j.plabm.2024.e00412 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFDiagn Pathol
September 2025
Department of Gastrointestinal Medical Oncology, Fudan University Shanghai Cancer Center, Shanghai, 200032, China.
Background: Gastric cancer is one of the most common cancers worldwide, with its prognosis influenced by factors such as tumor clinical stage, histological type, and the patient's overall health. Recent studies highlight the critical role of lymphatic endothelial cells (LECs) in the tumor microenvironment. Perturbations in LEC function in gastric cancer, marked by aberrant activation or damage, disrupt lymphatic fluid dynamics and impede immune cell infiltration, thereby modulating tumor progression and patient prognosis.
View Article and Find Full Text PDFHead Face Med
September 2025
Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Tübingen, Germany.
Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.
View Article and Find Full Text PDFFluids Barriers CNS
September 2025
Department of Medical Sciences, Neurology, Uppsala University, Uppsala, Sweden.
Background: Idiopathic normal pressure hydrocephalus (iNPH) predominantly manifests with gait disturbances, yet clinical assessments are vulnerable to confirmation bias, particularly post-shunt surgery. Blinded video evaluations are a method to enhance objectivity in gait assessment, but their reliability has never been systematically investigated. The aim was to evaluate the inter-rater reliability of blinded gait assessments in iNPH patients and to investigate how these assessments correlate with the Hellström iNPH scale and patient-reported health status following shunt surgery.
View Article and Find Full Text PDF