A novel integrated lateral flow immunoassay platform for the detection of cardiac troponin I using hierarchical dendritic copper-nickel nanostructures.

Talanta

Guangxi Key Laboratory of Electrochemical and Magneto-chemical Functional Materials, College of Chemistry and Bioengineering, Guilin University of Technology, Guilin, 541004, China; College of Environmental Science and Engineering, Guilin University of Technology, Guilin, 541004, China. Electronic a

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cardiac troponin I (cTnI) is a critical biomarker for the diagnosis of acute myocardial infarction (AMI). Herein, we report a novel integrated lateral flow immunoassay (LFIA) platform for highly sensitive point-of-care testing (POCT) of cTnI using hierarchical dendritic copper-nickel (HD-nanoCu-Ni) nanostructures. The electrodeposited HD-nanoCu-Ni film (∼22 μm thick) on an ITO-coated glass substrate exhibits superior capillary action and structural integrity. These properties enable efficient sample transport and antibody immobilization, making it a compelling alternative to conventional multi-component paper-based LFIA test strips, which are often plagued by structural fragility and susceptibility to moisture damage. The biofunctionalized HD-nanoCu-Ni substrates were laser-etched with lateral flow channels, including a sample loading/conjugate release zone, a test zone, and a control zone. Numerical simulations were used to further optimize the design of these channels to achieve optimal fluid flow and target capture. The HD-nanoCu-Ni LFIA device utilizes a fluorescence quenching based sandwich immunoassay format using antibody-labeled gold nanoparticles (AuNPs) as quenchers. Two different fluorescent materials, fluorescein isothiocyanate (FITC) and CdSe@ZnS quantum dots (QDs), were used as background fluorophores in the device. Upon the formation of a sandwich immunocomplex with cTnI on the HD-nanoCu-Ni device, introduced AuNPs led to the fluorescence quenching of the background fluorophores. The total assay time was approximately 15 min, demonstrating the rapid and efficient nature of the HD-nanoCu-Ni LFIA platform. For FITC, both inner filter effect (IFE) and fluorescence resonance energy transfer (FRET) contributed to the AuNP-mediated quenching. In the case of CdSe@ZnS QDs, IFE dominated the AuNP-induced quenching. Calibration curves were established based on the relationship between the fluorescence quenching intensity and cTnI concentration in human serum samples, ranging from 0.5 to 128 ng/mL. The limits of detection (LODs) were determined to be 0.27 ng/mL and 0.40 ng/mL for FITC and CdSe@ZnS QDs, respectively. A method comparison study using Passing-Bablok regression analysis on varying cTnI concentrations in human serum samples confirmed the equivalence of the HD-nanoCu-Ni LFIA platform to a commercial fluorescence cTnI LFIA assay kit, with no significant systematic or proportional bias observed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2024.126332DOI Listing

Publication Analysis

Top Keywords

lateral flow
12
lfia platform
12
hd-nanocu-ni lfia
12
fluorescence quenching
12
novel integrated
8
integrated lateral
8
flow immunoassay
8
cardiac troponin
8
hierarchical dendritic
8
dendritic copper-nickel
8

Similar Publications

Fine-tuning the dispersion of active suspensions with oscillatory flows.

Philos Trans A Math Phys Eng Sci

September 2025

Department of Mathematics, University of York, York, UK.

The combined effect of axial stretching and cross-stream diffusion on the downstream transport of solute is termed Taylor dispersion. The dispersion of active suspensions is qualitatively distinct: viscous and external torques can establish non-uniform concentration fields with weighted access to shear, modifying mean drift and effective diffusivity. It would be advantageous to fine-tune the dispersion for systems such as bioreactors, where mixing or particle separation can improve efficacy.

View Article and Find Full Text PDF

In recent AI-driven disease diagnosis, the success of models has depended mainly on extensive data sets and advanced algorithms. However, creating traditional data sets for rare or emerging diseases presents significant challenges. To address this issue, this study introduces a direct-self-attention Wasserstein generative adversarial network (DSAWGAN) designed to improve diagnostic capabilities in infectious diseases with limited data availability.

View Article and Find Full Text PDF

Biophysically Constrained Dynamical Modelling of the Brain Using Multimodal Magnetic Resonance Imaging.

Brain Res Bull

September 2025

Department of Psychiatry, Keck School of Medicine, University of Southern California, Los Angeles, CA; Institute for the Developing Mind, Children's Hospital Los Angeles, Los Angeles, CA.

We propose a Biophysically Restrained Analog Integrated Neural Network (BRAINN), an analog electrical network that models the dynamics of brain function. The network interconnects analog electrical circuits that simulate two tightly coupled brain processes: (1) propagation of an action potential, and (2) regional cerebral blood flow in response to the metabolic demands of signal propagation. These two processes are modeled by two branches of an electrical circuit comprising a resistor, a capacitor, and an inductor.

View Article and Find Full Text PDF

Rapid detection of carbapenemases in multiresistant Gram-negative strains: evaluation of two tests.

Microbiol Spectr

September 2025

Institute for Medical Laboratory Diagnostics, Helios University Hospital, Witten/Herdecke University, Wuppertal, Germany.

Carbapenem-resistant organisms (CRO) have rapidly spread worldwide in recent years, posing a significant challenge to both human health and healthcare systems. Timely and accurate detection of CRO, especially carbapenemase-producing and non-fermenters, is crucial for clinical prevention and treatment of these infections. In the present study, we subjected more than 114 multidrug-resistant Gram-negative and non-fermenters to two tests for the timely detection of carbapenemases.

View Article and Find Full Text PDF

Accurate point-of-care tools are needed to detect early nonadherence to daily HIV regimens and support timely transitions to long-acting options. Emerging evidence suggests that females may require higher adherence than males to achieve equivalent protection. Our next-generation urine tenofovir assay showed high accuracy across sexes but lower urine drug levels among female participants.

View Article and Find Full Text PDF