Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: CT-image segmentation for liver and hepatic vessels can facilitate liver surgical planning. However, time-consuming process and inter-observer variations of manual segmentation have limited wider application in clinical practice.
Purpose: Our study aimed to propose an automated deep learning (DL) segmentation algorithm for liver and hepatic vessels on portal venous phase CT images.
Methods: This retrospective study was performed to develop a coarse-to-fine DL-based algorithm that was trained, validated, and tested using private 413, 52, and 50 portal venous phase CT images, respectively. Additionally, the performance of the DL algorithm was extensively evaluated and compared with manual segmentation using an independent clinical dataset of preoperative contrast-enhanced CT images from 44 patients with hepatic focal lesions. The accuracy of DL-based segmentation was quantitatively evaluated using the Dice Similarity Coefficient (DSC) and complementary metrics [Normalized Surface Dice (NSD) and Hausdorff distance_95 (HD95) for liver segmentation, Recall and Precision for hepatic vessel segmentation]. The processing time for DL and manual segmentation was also compared.
Results: Our DL algorithm achieved accurate liver segmentation with DSC of 0.98, NSD of 0.92, and HD95 of 1.52 mm. DL-segmentation of hepatic veins, portal veins, and inferior vena cava attained DSC of 0.86, 0.89, and 0.94, respectively. Compared with the manual approach, the DL algorithm significantly outperformed with better segmentation results for both liver and hepatic vessels, with higher accuracy of liver and hepatic vessel segmentation (all p < 0.001) in independent 44 clinical data. In addition, the DL method significantly reduced the manual processing time of clinical postprocessing (p < 0.001).
Conclusions: The proposed DL algorithm potentially enabled accurate and rapid segmentation for liver and hepatic vessels using portal venous phase contrast CT images.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11302809 | PMC |
http://dx.doi.org/10.1002/acm2.14397 | DOI Listing |