A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

The catalytic hydro-dechlorination of 2, 4, 4' trichlorobiphenyl at mild temperatures and atmospheric pressure. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Polychlorinated biphenyls (PCBs), including all 209 congeners, are designated as persistent organic pollutants (POPs) due to their high toxicity and bioaccumulation in human bodies and the ecosystem. The need for PCB remediation still remains long after their production ban. In this study, a catalytic hydro-dechlorination (HDC) method was employed to dechlorinate 2,4,4'-trichlorobiphenyl (PCB 28), a congener found ubiquitously in multiple environmental media. The HDC of PCB 28 was experimentally studied at mild temperatures viz. ~20, 50, and ~77°C and atmospheric pressure. EtN (triethylamine) was added as a co-catalyst. The dechlorination rates increased with temperature as well as EtN dosage, and the HDC pathway was hypothesized based on the product and intermediates observed. The less chlorinated intermediates suggested that the position of the chlorine strongly impacted HDC rates, and the preference of HDC at para positions can be orders of magnitudes higher than the ortho. The activation energy was estimated in the range of 12.4-13.9 kJ/mole, indicating a diffusion-controlled HDC system. The remediation need for polychlorinated biphenyls (PCBs) still remains long after their production ban around the world. The development of low-cost methods is highly desirable, especially for developing countries, in response to the Stockholm Convention. In this study, the dechorination of a ubiquitously present PCB congener was studied using a catalytic hydro-dechlorination (HDC) method in low temperatures up to ~77°C and was able to achieve near 100% dechlorination in 6 hr. Results indicated that the HDC process can be performed under mild temperatures and atmospheric conditions and can be a potential solution to real world PCB contamination issues.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10962247.2024.2353643DOI Listing

Publication Analysis

Top Keywords

catalytic hydro-dechlorination
12
mild temperatures
12
temperatures atmospheric
8
atmospheric pressure
8
polychlorinated biphenyls
8
biphenyls pcbs
8
remains long
8
long production
8
production ban
8
hdc
8

Similar Publications