Multibranch Wavelet-Based Network for Image Demoiréing.

Sensors (Basel)

Department of Electrical Engineering, National Taiwan Normal University, Taipei 10610, Taiwan.

Published: April 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Moiré patterns caused by aliasing between the camera's sensor and the monitor can severely degrade image quality. Image demoiréing is a multi-task image restoration method that includes texture and color restoration. This paper proposes a new multibranch wavelet-based image demoiréing network (MBWDN) for moiré pattern removal. Moiré images are separated into sub-band images using wavelet decomposition, and demoiréing can be achieved using the different learning strategies of two networks: moiré removal network (MRN) and detail-enhanced moiré removal network (DMRN). MRN removes moiré patterns from low-frequency images while preserving the structure of smooth areas. DMRN simultaneously removes high-frequency moiré patterns and enhances fine details in images. Wavelet decomposition is used to replace traditional upsampling, and max pooling effectively increases the receptive field of the network without losing the spatial information. Through decomposing the moiré image into different levels using wavelet transform, the feature learning results of each branch can be fully preserved and fed into the next branch; therefore, possible distortions in the recovered image are avoided. Thanks to the separation of high- and low-frequency images during feature training, the proposed two networks achieve impressive moiré removal effects. Based on extensive experiments conducted using public datasets, the proposed method shows good demoiréing validity both quantitatively and qualitatively when compared with the state-of-the-art approaches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11086364PMC
http://dx.doi.org/10.3390/s24092762DOI Listing

Publication Analysis

Top Keywords

image demoiréing
12
moiré patterns
12
moiré removal
12
moiré
9
multibranch wavelet-based
8
images wavelet
8
wavelet decomposition
8
removal network
8
low-frequency images
8
image
7

Similar Publications

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.

Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.

View Article and Find Full Text PDF

Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.

View Article and Find Full Text PDF

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF