Impedance pneumography (IP) has provided static assessments of subjects' breathing patterns in previous studies. Evaluating the feasibility and limitation of ambulatory IP based respiratory monitoring needs further investigation on clinically relevant exercise designs. The aim of this study was to evaluate the capacity of an advanced IP in ambulatory respiratory monitoring, and its predictive value in independent ventilatory capacity quantification during cardiopulmonary exercise testing (CPET).35 volunteers were examined with the same calibration methodology and CPET exercise protocol comprising phases of rest, unloaded, incremental load, maximum load, recovery and further-recovery. In 3 or 4 deep breaths of calibration stage, thoracic impedance and criterion spirometric volume were simultaneously recorded to produce phase-specific prior calibration coefficients (CCs). The IP measurement during exercise protocol was converted by prior CCs to volume estimation curve and thus calculate minute ventilation (VE) independent from the spirometry approach.Across all measurements, the relative error of IP-derived VE (VE) and flowrate-derived VE (VE) was less than 13.8%. In Bland-Altman plots, the aggregate VE estimation bias was statistically insignificant for all 3 phases with pedaling exercise and the discrepancy between VEand VEfell within the 95% limits of agreement (95% LoA) for 34 or all subjects in each of all CPET phases.This work reinforces the independent use of IP as an accurate and robust alternative to flowmeter for applications in cycle ergometry CPET, which could significantly encourage the clinical use of IP and improve the convenience and comfort of CPET.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6579/ad4951 | DOI Listing |
Objective: This study evaluates the feasibility of a noninvasive system for monitoring diaphragmatic efficiency in people with cervical spinal cord injury (CSCI).
Methods: Two versions of a portable hardware system were developed using impedance pneumography (IP) to measure tidal volume (TV) and surface electromyography (sEMG) to assess diaphragm electrical activity (EAdi). Version 1 was used to determine optimal electrode positions, while Version 2 integrated these sensor systems into a compact, portable design.
Comput Biol Med
September 2025
Cerebrovascular Disease Research Center, Hallym University, Chuncheon, 24252, Republic of Korea; Department of Artificial Intelligence Convergence, Hallym University, Chuncheon, 24252, Republic of Korea; Department of Neurology, College of Medicine, Hallym University, Chuncheon, 24252, Republic of K
Sleep staging is critical for investigating sleep quality and detecting disorders. Polysomnography (PSG) remains the gold standard, but is costly and impractical for routine monitoring. This study evaluates the feasibility of a patch-type wearable device using single-lead electrocardiography (ECG) and impedance pneumography (IPG) for multi-stage sleep classification.
View Article and Find Full Text PDFPsychophysiology
February 2025
Department of Biological Psychology, VU Amsterdam, Amsterdam, the Netherlands.
Speech production interferes with the measurement of changes in cardiac vagal activity during acute stress by attenuating the expected drop in heart rate variability. Speech also induces cardiac sympathetic changes similar to those induced by psychological stress. In the laboratory, confounding of physiological stress reactivity by speech may be controlled experimentally.
View Article and Find Full Text PDFPhysiol Meas
May 2024
School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China.
Impedance pneumography (IP) has provided static assessments of subjects' breathing patterns in previous studies. Evaluating the feasibility and limitation of ambulatory IP based respiratory monitoring needs further investigation on clinically relevant exercise designs. The aim of this study was to evaluate the capacity of an advanced IP in ambulatory respiratory monitoring, and its predictive value in independent ventilatory capacity quantification during cardiopulmonary exercise testing (CPET).
View Article and Find Full Text PDFJ Clin Anesth
June 2024
Goethe University Frankfurt, University Hospital, Department of Internal Medicine 1, Frankfurt am Main, Germany.
Study Objective: To assess the efficacy of an ECG-based method called thoracic impedance pneumography to reduce hypoxic events in endoscopy.
Design: This was a single center, 1:1 randomized controlled trial.
Setting: The trial was conducted during the placement of percutaneous endoscopic gastrostomy (PEG).