98%
921
2 minutes
20
Introduction: Since the 2018 change in the US adult heart allocation policy, more patients are bridged-to-transplant on temporary mechanical circulatory support (tMCS). Previous studies indicate that durable left ventricular assist devices (LVAD) may lead to allosensitization. The goal of this study was to assess whether tMCS implantation is associated with changes in sensitization.
Methods: We included patients evaluated for heart transplants between 2015 and 2022 who had alloantibody measured before and after MCS implantation. Allosensitization was defined as development of new alloantibodies after tMCS implant.
Results: A total of 41 patients received tMCS before transplant. Nine (22.0%) patients developed alloantibodies following tMCS implantation: 3 (12.0%) in the intra-aortic balloon pump group (n = 25), 2 (28.6%) in the microaxial percutaneous LVAD group (n = 7), and 4 (44.4%) in the veno-arterial extra-corporeal membrane oxygenation group (n = 9)-p = .039. Sensitized patients were younger (44.7 ± 11.6 years vs. 54.3 ± 12.5 years, p = .044), were more likely to be sensitized at baseline - 3 of 9 (33.3%) compared to 2 out of 32 (6.3%) (p = .028) and received more transfusions with red blood cells (6 (66.6%) vs. 8 (25%), p = .02) and platelets (6 (66.6%) vs. 5 (15.6%), p = .002). There was no significant difference in tMCS median duration of support (4 [3,15] days vs. 8.5 [5,14.5] days, p = .57). Importantly, out of the 11 patients who received a durable LVAD after tMCS, 5 (45.5%) became sensitized, compared to 4 out of 30 patients (13.3%) who only had tMCS-p = .028.
Conclusions: Our findings suggest that patients bridged-to-transplant with tMCS, without significant blood product transfusions and a subsequent durable LVAD implant, have a low risk of allosensitization. Further studies are needed to confirm our findings and determine whether risk of sensitization varies by type of tMCS and duration of support.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11283677 | PMC |
http://dx.doi.org/10.1111/ctr.15330 | DOI Listing |
J Phys Chem Lett
September 2025
Key Laboratory of Theoretical and Computational Photochemistry, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, China.
In this work, we present a machine learning (ML) approach for predicting the optimal range separation parameters in transition metal complexes (TMCs), aiming to reduce the computational cost associated with optimally tuned range-separated hybrid (OT-RSH) functionals while preserving their accuracy. A data set containing 4380 TMCs was constructed by screening the tmQM database, with each TMC represented by a 62 087-dimensional multiple-fingerprint feature (MFF) vector and labeled with its optimally tuned range separation parameter. Multiple regression models were applied to train the prediction model, and the support vector machine (SVM) model yielded the best performance.
View Article and Find Full Text PDFACS Nano
September 2025
Key Laboratory of Applied Surface and Colloid Chemistry (Ministry of Education), School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710119, P. R. China.
Transition metal chalcogenides (TMCs) have garnered significant attention as high-capacity anode materials, yet the unconventional role of the Cu collector meditating atomic-level substitution of metal-site cations by Cu ions during electrochemical cycling remains mechanistically unclear. To address this, herein, Cu-doped MoSe@C ultrathin nanosheets were synthesized via the solvothermal process and carbonization strategies. A systematic investigation was conducted to elucidate the underlying driving forces for Cu substitution at Mo sites and the crucial regulatory effects of solid electrolyte interphase (SEI) formation.
View Article and Find Full Text PDFAdv Sci (Weinh)
September 2025
Department of Otolaryngology-Head and Neck Surgery, Stanford University, Palo Alto, 94304, USA.
The plasma membrane is actively regulated by lipid transporters that create electrochemical gradients between leaflets, and passively by scramblases that dissipate these gradients. Membrane properties such as lipid packing are critical for the proper function of transmembrane proteins, particularly mechanosensitive ion channels. Mechanosensation is a key component of many sensory processes including balance, and hearing.
View Article and Find Full Text PDFJACC Cardiovasc Interv
August 2025
Cardiac Intensive Care Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy.
The increasing use of microaxial flow pumps (mAFP) underpins the need for a comprehensive approach to manage critically ill patients in an effort to maximize the benefits of this temporary mechanical circulatory support (tMCS) while minimizing its potential complications. Multimodality cardiac imaging offers an irreplaceable array of tools to address device position, device-heart hemodynamic interaction, myocardial recovery assessment, and identification of complications. This review provides a comprehensive and pragmatic summary of the cardiovascular imaging modalities currently available throughout the pathway of care of mAFP-supported patients, from device insertion, to intensive cardiac care hemodynamic monitoring, weaning guidance, and myocardial recovery assessment.
View Article and Find Full Text PDFEur Heart J Qual Care Clin Outcomes
August 2025
Centennial Heart at Parkridge, Parkridge Medical Center, Chattanooga, TN, USA.
Background: Racial disparities in outcomes for patients requiring temporary mechanical circulatory support (tMCS) after acute myocardial infarction (AMI) remain unclear.
Objective: To evaluate racial disparities in patients requiring tMCS following AMI.
Methods: Using the TriNetX US collaborative network (2009-2023), we identified non-Hispanic Black (NHB) and non-Hispanic White (NHW) adults who had AMI and required tMCS.