A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Absolute quantification methods for Prostate-Specific antigen by Isotope-Dilution mass spectrometry. | LitMetric

Absolute quantification methods for Prostate-Specific antigen by Isotope-Dilution mass spectrometry.

J Chromatogr B Analyt Technol Biomed Life Sci

Division of Chemical Metrology and Analytical Science, National Institute of Metrology, Beijing 100029, China. Electronic address:

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Prostate-specific antigen (PSA) is a diagnostic marker for prostate cancer; however, because it is a macromolecular glycoprotein with complex and diverse isoforms, it is difficult to standardize clinical PSA detection results. To overcome this limitation, herein, naturally extracted PSA was characterized as free PSA (fPSA), and the PSA solution was successfully quantified by amino acid analysis coupled with isotope-dilution mass spectrometry (AAA-IDMS) and enzymatic hydrolysis-IDMS; the results could be traced to the International System of Units (SI) through absolutely quantified amino acids and peptides. After protein hydrolysis or digestion condition optimization, amino acids and signature peptides were detected by liquid chromatography-mass spectrometry with the multiple reaction monitoring mode. The mass concentrations of PSA obtained through AAA-IDMS and enzymatic hydrolysis-IDMS were (75.3 ± 1.5) µg/g (k = 2) and (74.7 ± 1.7) µg/g (k = 2), respectively. The PSA weighted average mass concentration was (75.0 ± 1.6) µg/g (k = 2). The consistency assessment between the two methods was successfully validated, ensuring absolute quantitative accuracy. This study lays the foundation for the development of high-order reference materials for the clinical detection of PSA, which can improve the accuracy, reliability, and consistency of clinical PSA test results.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jchromb.2024.124112DOI Listing

Publication Analysis

Top Keywords

µg/g k = 2
12
psa
9
prostate-specific antigen
8
isotope-dilution mass
8
mass spectrometry
8
clinical psa
8
quantified amino
8
aaa-idms enzymatic
8
enzymatic hydrolysis-idms
8
amino acids
8

Similar Publications