Article Abstract

Purpose: This study aimed to explore whether a meaningful improvement in physical performance following an in-season strength training intervention can be related to external load match parameters at an individual level in professional male football players.

Methods: Eight male professional football players (25.4 ± 3.1 years, 184.1 ± 3.4 cm, 79.3 ± 2.2 kg) completed a 10-week strength intervention period in addition to football-specific training and matches. Commonly used physical and external load measures were assessed before and after intervention. Physical performance improvements had to exceed the measurement's typical error and the smallest worthwhile difference (SWD) to be considered meaningful. External load match parameters were assessed before and after the intervention period using SWD and non-overlap of all pairs (NAP) analysis. A Bayesian pairwise correlation analysis was performed to evaluate relationships between changes in physical performance and external load match parameters.

Results: Three players displayed meaningful improvements in two to five physical performance measures. However, positive changes exceeding the SWD and positive effects in NAP results were observed for all players in external load match parameters. Kendall's tau correlation analysis showed evidence (base factor >3) for only one correlation (maximum speed - decelerations,  = -0.62) between the changes in physical performance and external load measures, while the remaining comparisons exhibited no relation.

Conclusions: The findings suggest that improvements in physical performance may not necessarily translate to improvements in external load match parameters. Further research, with larger sample sizes, is needed to understand potential mechanisms between acute and chronic physical performance changes and football external load parameters during training and matches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11045924PMC
http://dx.doi.org/10.3389/fspor.2024.1367894DOI Listing

Publication Analysis

Top Keywords

external load
36
physical performance
28
load match
24
match parameters
20
physical
9
external
9
load
9
improvements external
8
male professional
8
professional football
8

Similar Publications

Fractional-order adaptive fuzzy decentralized tracking control for steer-by-wire system.

ISA Trans

August 2025

Department of Vehicle Engineering and Jiangsu Engineering Research Center of Vehicle Distributed Drive and Intelligent Wire Control Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China; Department of Vehicle Engineering and Jiangsu Engineering Research Center of Vehi

The steer-by-wire (SbW) system, as the core component of vehicle steering, needs to track the front wheel angle accurately. To mitigate the angle tracking accuracy degradation caused by D-Q axes coupling, time-varying motor electrical parameters, and load disturbance, a fractional-order adaptive fuzzy decentralized tracking control (FAFDTC) strategy is proposed in this paper. First, considering time-varying motor parameters, D-Q axes coupling, and fractional-order characteristics of components, a fractional-order SbW interconnected system is constructed to enhance its ability to characterize nonlinearities, time-varying dynamics, and system coupling.

View Article and Find Full Text PDF

This study investigated how the acceleration-speed profile (ASP) of the weaker and stronger side changes at different radii. Twenty male youth soccer players completed 30 m linear and curvilinear sprints (12.15, 11.

View Article and Find Full Text PDF

Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary noninvasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered.

View Article and Find Full Text PDF

Background: This study aimed to evaluate how subscapularis tendon repair influences joint loads in relation to humeral offset and arm position.

Patients And Methods: Two fresh-frozen, whole-body cadaveric shoulders underwent a reverse total shoulder arthroplasty (rTSA) on the humeral side using an internal proprietary load-sensing system (LSS) (Goldilocks, Statera Medical, Montreal, Canada). In addition to three "complex" Activity Daily Life positions ("behind the back", "overhead reach", and "across the chest"), four standard postures (external rotation, extension, abduction, and flexion) were used to record the glenohumeral loads (Newtons) and their locations applied to the implant.

View Article and Find Full Text PDF

Electroactive polymer (EAP) artificial muscles are gaining attention in robotic control technologies. Among them, the development of self-sensing actuators that integrate sensing mechanisms within artificial muscles is highly anticipated. This study aimed to evaluate the accuracy and precision of the sensing capabilities of the e-Rubber (eR), an artificial muscle developed by Toyoda Gosei Co.

View Article and Find Full Text PDF