Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unlabelled: We investigated the accuracy of (ICD) codes for the identification of veterans with rapid eye movement sleep behavior disorder. The charts of 139 randomly sampled veterans with ≥ 1 ICD-9 and ICD-10 code(s) for rapid eye movement sleep behavior disorder were reviewed for documentation of a suspected, previous, or current diagnosis; clinical symptoms; and/or empiric treatments for this disorder. Notably, 71 (51.1%) patients with rapid eye movement sleep behavior disorder electronic diagnoses had not undergone polysomnography, and 29 (20.9%) had polysomnography reports without commentary on rapid eye movement sleep without atonia. Sleep centers are therefore encouraged to include a brief sentence in polysomnography report templates commenting on the presence/absence of rapid eye movement sleep without atonia.

Citation: Jones MB, Schenck CH, Azarian M, Jorge RE, Sharafkhaneh A, Razjouyan J. Validation of electronic diagnostic codes for rapid eye movement sleep behavior disorder. 2024;20(8);1387-1389.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11294125PMC
http://dx.doi.org/10.5664/jcsm.11190DOI Listing

Publication Analysis

Top Keywords

rapid eye
28
eye movement
28
movement sleep
28
sleep behavior
20
behavior disorder
20
codes rapid
12
validation electronic
8
electronic diagnostic
8
diagnostic codes
8
sleep
8

Similar Publications

Children with amblyopia read slower than their peers during binocular viewing. Ocular motor dysfunction typical of amblyopia may cause slow reading. It is unclear whether this is due to fixation instability or increased forward saccades.

View Article and Find Full Text PDF

Objective: To clarify the potential risks and causative mechanisms of glare from nighttime road fill lights on driving safety, this study investigates the dual interference of glare-induced visual cognitive load and physiological stress.

Methods: A field driving experiment involving 20 drivers was conducted, with real-time collection of visual data (e.g.

View Article and Find Full Text PDF

Acute sleep deprivation (SD) rapidly alleviates depression, addressing a critical gap in mood disorder treatment. Rapid eye movement SD (REM SD) modulates the excitability of vasoactive intestinal peptide (VIP) neurons, influencing the synaptic plasticity of pyramidal neurons. However, the precise mechanism remains undefined.

View Article and Find Full Text PDF

Objectives: To describe the research principles and cohort characteristics of the multi-disciplinary Project HERCULES, an innovative model of safe high-volume outpatient eye-care service for patients with stable chronic eye diseases. Results and analyses of the workstreams within Project HERCULES will be reported elsewhere. The rationale was to improve eye-care capacity in the National Health Service (NHS) in England through the creation of technician-delivered monitoring in a large retail-unit in a London shopping-centre, with remote asynchronous review of results by clinicians (named Eye-Testing and Review through Asynchronous Clinic (Eye-TRAC)).

View Article and Find Full Text PDF

Purpose: Melbourne rapid fields (MRF) online perimetry is web-based software that allows white-on-white threshold perimetry using any computer. This study assesses the perimetric outcomes of MRF10-2 protocol via laptop computer in comparison to Humphrey field analyzer (HFA).

Methods: This prospective and cross-sectional study included 91 eyes from 91 Japanese glaucoma patients.

View Article and Find Full Text PDF