The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.01 m 2 undergoing a safe and effective HeartMate3 implantation despite extremely small thoracic dimensions. Using computed tomography-derived three-dimensional (3D) reconstruction, it was possible to simulate several device positions finding the best HeartMate3 lodging. Simulation-guided pump placement was then obtained in the operating room. Normal HeartMate3 functioning was registered until heart transplant. Our experience shows that preoperative planning and virtual fitting simulation can be effective to assess safety of HeartMate3 implantation even in small children. The 3D reconstruction and simulation may help to increase the pool of children candidates for this device, even though a larger experience is needed to assess the risk profile of the HeartMate3 in such small patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11139228 | PMC |
http://dx.doi.org/10.1097/MAT.0000000000002069 | DOI Listing |
Cureus
July 2024
Department of Cardiology/Advanced Heart Failure, Heart Transplant and Pulmonary Hypertension, Hartford Hospital, Hartford, USA.
Right ventricular failure (RVF) is a common complication that occurs after a left ventricular assist device (LVAD) is implanted. We report an interesting case of severe and refractory hypoxia during the early postoperative period after HeartMate3 (HM3) (Abbott Laboratories, Lake Forest, IL) implantation resulting in the unmasking of a right-to-left intracardiac shunt through a patent foramen ovale (PFO), triggered by early RVF. Importantly, the patient had a small left-to-right shunt after receiving a left-sided Impella 5.
View Article and Find Full Text PDFASAIO J
June 2024
From the Pediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
The current use of intracorporeal left ventricular assist devices in children is still limited by small body dimensions. Many children weighing of less than 30 kg requiring durable mechanical circulatory support are implanted with the Berlin Heart EXCOR, a paracorporeal device. We present the case of a girl aged 10 years with a body surface area of 1.
View Article and Find Full Text PDFJ Artif Organs
June 2023
Department of Cardiovascular Surgery, National Cerebral and Cardiovascular Center, 6-1 Kishibeshimmachi, Suita, Osaka, 564-8565, Japan.
Implantation of left ventricular assist device (LVAD) for arrhythmogenic right ventricular (RV) cardiomyopathy is challenging associated with small LV cavity, laterally dislocated LV apex, thin and fragile RV free wall. A 43-year-old male with more than 10 years of medical treatment developed congestive heart failure related to biventricular failure. Durable LVAD was indicated to prevent further deterioration of the RV function, which would be exacerbated by progression of LV dysfunction.
View Article and Find Full Text PDF