Bridge plating is an effective adjunct treatment for complex elbow instability.

J Shoulder Elbow Surg

Department of Surgery, St. Joseph's Health Care, Hand and Upper Limb Centre, Western University, London, ON, Canada. Electronic address:

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Managing persistent elbow instability and chronic dislocations presents challenges despite traditional treatments. Supplementary methods like immobilization and various fixations, though common, can carry high complication rates. This study assesses the efficacy of bridge plating in treating complex elbow instability through a retrospective review of patients. Data on characteristics, treatment duration, range of motion, complications, and evaluation scores were analyzed, providing insights into outcomes complications associated with bridge plating.

Results: Eleven patients were reviewed at a mean follow-up of 80 ± 68 weeks postoperatively. The mean age was 53 ± 14 years and there were 5 females and 6 males. The mean body mass index was 38. Bridge plating was used for a spectrum of complex elbow injuries. The mean time from injury to bridge plating in acute cases was 29 ± 19 days and 344 ± 381 days in chronic cases. The mean duration of bridge plating was 121 ± 72 days. At the time of plate removal, mean intraoperative elbow motion was extension 58° ± 12°, flexion 107° ± 14°, supination 66° ± 23° and pronation 60° ± 26°. At the latest follow-up visit, mean elbow motion was extension 37° ± 22°, flexion 127° ± 17°, supination 72° ± 15°, and pronation 63° ± 18°. There were 6 complications (55%): heterotopic ossification, ulnar neuropathy, wound failure over the plate in a thin patient, an ulnar shaft periprosthetic fracture due to a seizure-induced fall, and persistent elbow subluxation despite bridge plate fixation. Finally, 1 patient sustained a fracture of a 3.5-mm locking bridge plate. One patient required a contracture release for persistent stiffness. Four of these complications can be directly attributed to the use of the bridge plate (36%). At final follow-up, the mean patient-rated elbow evaluation score was 34, with 0 indicating no pain and disability. The mean Single Assessment Numeric Evaluation score was 66% for the 8 patients who had this available, with 100% being the best possible attainable score.

Conclusion: Bridge plating effectively maintains joint reduction in selected complex elbow instability cases. However, patients with bridge plates often require a second surgery for removal and experience high rates of general complications because of the complexity of their condition.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2024.03.013DOI Listing

Publication Analysis

Top Keywords

bridge plating
24
complex elbow
16
elbow instability
16
bridge plate
12
bridge
11
elbow
9
persistent elbow
8
elbow motion
8
motion extension
8
evaluation score
8

Similar Publications

Background/objective: Plate failure, including bending, is a critical issue in orthopedic fracture fixation, with clinical failure rates of 3.5%-19%, burdening patients and healthcare systems. Preclinical ovine models have observed similar plate bending due to overloading.

View Article and Find Full Text PDF

Background: Dorsal wrist spanning plate (DWSP) fixation in distal radius fractures (DRFs) has been proposed to allow earlier mobilization in polytraumatized patients by enabling early weightbearing (WB) through the injured wrist. The purpose of this study is to compare radiographic and clinical outcomes in patients who bore weight through the injured wrist within the early postoperative period with patients who did not bear weight.

Methods: Patients who underwent DWSP fixation at a single institution were retrospectively identified.

View Article and Find Full Text PDF

Aims: Inferior positioning of the calcar screw is important in the purchase of medial screws when treating proximal humeral fractures with a locking plate. However, the impact of the overall trajectory of the calcar screw has not been investigated. The aim of this study was to investigate whether the failure of a calcar screw to purchase both proximal and distal fragments would contribute to an increased risk of failure of fixation in these patients.

View Article and Find Full Text PDF

Does the addition of demineralized bone matrix to fixation of acute comminuted clavicle fractures affect healing outcomes?

Eur J Orthop Surg Traumatol

August 2025

Division of Orthopedic Trauma Surgery, Department of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 E 17th Street, New York, NY, 10003, USA.

Purpose: To assess the healing outcomes of patients who sustained a comminuted clavicle fracture and underwent operative fixation with or without the addition of demineralized bone matrix (DBM).

Methods: A total of 271 comminuted midshaft clavicle fractures that presented to our hospital system and underwent operative fixation with a plate and screw construct were retrospectively reviewed. Data collected include patient demographics, initial injury information, and use of demineralized bone matrix during surgery to enhance bone healing.

View Article and Find Full Text PDF

Hydrogen fuel cell bipolar plates demand surfaces with an atomically smooth morphology and stable electrochemical interfaces to minimize contact resistance and corrosion degradation. While nickel-titanium (NiTi) alloys offer inherent advantages for this role, their practical deployment is hindered by persistent surface defects (e.g.