98%
921
2 minutes
20
Background: Managing persistent elbow instability and chronic dislocations presents challenges despite traditional treatments. Supplementary methods like immobilization and various fixations, though common, can carry high complication rates. This study assesses the efficacy of bridge plating in treating complex elbow instability through a retrospective review of patients. Data on characteristics, treatment duration, range of motion, complications, and evaluation scores were analyzed, providing insights into outcomes complications associated with bridge plating.
Results: Eleven patients were reviewed at a mean follow-up of 80 ± 68 weeks postoperatively. The mean age was 53 ± 14 years and there were 5 females and 6 males. The mean body mass index was 38. Bridge plating was used for a spectrum of complex elbow injuries. The mean time from injury to bridge plating in acute cases was 29 ± 19 days and 344 ± 381 days in chronic cases. The mean duration of bridge plating was 121 ± 72 days. At the time of plate removal, mean intraoperative elbow motion was extension 58° ± 12°, flexion 107° ± 14°, supination 66° ± 23° and pronation 60° ± 26°. At the latest follow-up visit, mean elbow motion was extension 37° ± 22°, flexion 127° ± 17°, supination 72° ± 15°, and pronation 63° ± 18°. There were 6 complications (55%): heterotopic ossification, ulnar neuropathy, wound failure over the plate in a thin patient, an ulnar shaft periprosthetic fracture due to a seizure-induced fall, and persistent elbow subluxation despite bridge plate fixation. Finally, 1 patient sustained a fracture of a 3.5-mm locking bridge plate. One patient required a contracture release for persistent stiffness. Four of these complications can be directly attributed to the use of the bridge plate (36%). At final follow-up, the mean patient-rated elbow evaluation score was 34, with 0 indicating no pain and disability. The mean Single Assessment Numeric Evaluation score was 66% for the 8 patients who had this available, with 100% being the best possible attainable score.
Conclusion: Bridge plating effectively maintains joint reduction in selected complex elbow instability cases. However, patients with bridge plates often require a second surgery for removal and experience high rates of general complications because of the complexity of their condition.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jse.2024.03.013 | DOI Listing |
J Orthop Translat
November 2025
AO Research Institute Davos, Davos, Switzerland.
Background/objective: Plate failure, including bending, is a critical issue in orthopedic fracture fixation, with clinical failure rates of 3.5%-19%, burdening patients and healthcare systems. Preclinical ovine models have observed similar plate bending due to overloading.
View Article and Find Full Text PDFHand (N Y)
September 2025
Duke University, Durham, NC, USA.
Background: Dorsal wrist spanning plate (DWSP) fixation in distal radius fractures (DRFs) has been proposed to allow earlier mobilization in polytraumatized patients by enabling early weightbearing (WB) through the injured wrist. The purpose of this study is to compare radiographic and clinical outcomes in patients who bore weight through the injured wrist within the early postoperative period with patients who did not bear weight.
Methods: Patients who underwent DWSP fixation at a single institution were retrospectively identified.
Bone Joint J
September 2025
Department of Orthopaedic Surgery, Korea University Anam Hospital, Seoul, South Korea.
Aims: Inferior positioning of the calcar screw is important in the purchase of medial screws when treating proximal humeral fractures with a locking plate. However, the impact of the overall trajectory of the calcar screw has not been investigated. The aim of this study was to investigate whether the failure of a calcar screw to purchase both proximal and distal fragments would contribute to an increased risk of failure of fixation in these patients.
View Article and Find Full Text PDFEur J Orthop Surg Traumatol
August 2025
Division of Orthopedic Trauma Surgery, Department of Orthopedic Surgery, NYU Langone Health, NYU Langone Orthopedic Hospital, 301 E 17th Street, New York, NY, 10003, USA.
Purpose: To assess the healing outcomes of patients who sustained a comminuted clavicle fracture and underwent operative fixation with or without the addition of demineralized bone matrix (DBM).
Methods: A total of 271 comminuted midshaft clavicle fractures that presented to our hospital system and underwent operative fixation with a plate and screw construct were retrospectively reviewed. Data collected include patient demographics, initial injury information, and use of demineralized bone matrix during surgery to enhance bone healing.
Langmuir
September 2025
College of Mechanical and Electric Engineering, Changchun University of Science and Technology, Changchun 130022, China.
Hydrogen fuel cell bipolar plates demand surfaces with an atomically smooth morphology and stable electrochemical interfaces to minimize contact resistance and corrosion degradation. While nickel-titanium (NiTi) alloys offer inherent advantages for this role, their practical deployment is hindered by persistent surface defects (e.g.
View Article and Find Full Text PDF