98%
921
2 minutes
20
The kidney's microstructure, which comprises a highly convoluted tubular and vascular network, can only be partially revealed using classical 2D histology. Considering that the kidney's microstructure is closely related to its function and is often affected by pathologies, there is a need for powerful and high-resolution 3D imaging techniques to visualize the microstructure. Here, we present how cryogenic contrast-enhanced microCT (cryo-CECT) allowed 3D visualization of glomeruli, tubuli, and vasculature. By comparing different contrast-enhancing staining agents and freezing protocols, we found that the preferred sample preparation protocol was the combination of staining with 1:2 hafnium(IV)-substituted Wells-Dawson polyoxometalate and freezing by submersion in isopentane at -78°C. This optimized protocol showed to be highly sensitive, allowing to detect small pathology-induced microstructural changes in a mouse model of mild trauma-related acute kidney injury after thorax trauma and hemorrhagic shock. In summary, we demonstrated that cryo-CECT is an effective 3D histopathological tool that allows to enhance our understanding of kidney tissue microstructure and their related function.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11022514 | PMC |
http://dx.doi.org/10.1155/2024/3924036 | DOI Listing |
Acta Biomater
May 2025
Department of Medical Oncology, Fudan University Shanghai Cancer Center, Shanghai Medical College, Fudan University, Shanghai 200032, China. Electronic address:
Microwave ablation (MWA) is widely recognized as an effective radical therapy for hepatocellular carcinoma (HCC). However, local ablation often results in a high risk of tumor recurrence. To address this challenge, we developed an effective anticancer drug delivery system comprising arsenic trioxide (AsO)-loaded polyethylene glycol-dipalmitoylphosphatidylethanolamine (mPEG-DPPE) calcium phosphate nanoparticles (AsONPs) encapsulated within an injectable thermoresponsive hydrogel (ANPs-Gel).
View Article and Find Full Text PDFJ Anat
November 2024
UCLouvain-IREC, Morphology Lab (MORF), Brussels, Belgium.
Transplant Direct
June 2024
Leuven Intestinal Failure and Transplantation (LIFT) Center, University Hospitals Leuven, Leuven, Belgium.
Background: Failure to close the abdominal wall after intestinal transplantation (ITx) or multivisceral Tx remains a surgical challenge. An attractive method is the use of nonvascularized rectus fascia (NVRF) in which both layers of the donor abdominal rectus fascia are used as an inlay patch without vascular anastomosis. How this graft integrates over time remains unknown.
View Article and Find Full Text PDFInt J Biomed Imaging
April 2024
Department of Materials Engineering, KU Leuven, Heverlee, Belgium.
The kidney's microstructure, which comprises a highly convoluted tubular and vascular network, can only be partially revealed using classical 2D histology. Considering that the kidney's microstructure is closely related to its function and is often affected by pathologies, there is a need for powerful and high-resolution 3D imaging techniques to visualize the microstructure. Here, we present how cryogenic contrast-enhanced microCT (cryo-CECT) allowed 3D visualization of glomeruli, tubuli, and vasculature.
View Article and Find Full Text PDFThe characterization of inverted structures (crystallographic, ferroelectric, or magnetic domains) is crucial in the development and application of novel multi-state devices. However, determining these inverted structures needs a sensitive probe capable of revealing their phase correlation. Here a contrast-enhanced phase-resolved second harmonic generation (SHG) microscopy is presented, which utilizes a phase-tunable Soleil-Babinet compensator and the interference between the SHG fields from the inverted structures and a homogeneous reference.
View Article and Find Full Text PDF