98%
921
2 minutes
20
Researchers who study the human hippocampus are naturally interested in how its subfields function. However, many researchers are precluded from examining subfields because their manual delineation from magnetic resonance imaging (MRI) scans (still the gold standard approach) is time consuming and requires significant expertise. To help ameliorate this issue, we present here two protocols, one for 3T MRI and the other for 7T MRI, that permit automated hippocampus segmentation into six subregions, namely dentate gyrus/cornu ammonis (CA)4, CA2/3, CA1, subiculum, pre/parasubiculum, and uncus along the entire length of the hippocampus. These protocols are particularly notable relative to existing resources in that they were trained and tested using large numbers of healthy young adults (n = 140 at 3T, n = 40 at 7T) whose hippocampi were manually segmented by experts from MRI scans. Using inter-rater reliability analyses, we showed that the quality of automated segmentations produced by these protocols was high and comparable to expert manual segmenters. We provide full open access to the automated protocols, and anticipate they will save hippocampus researchers a significant amount of time. They could also help to catalyze subfield research, which is essential for gaining a full understanding of how the hippocampus functions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/hipo.23606 | DOI Listing |
Appl Biosaf
August 2025
Global Center for Health Security, University of Nebraska Medical Center, Omaha, Nebraska, USA.
Introduction: Laboratory-acquired infections (LAIs) from exposure to infectious biological pathogens during laboratory operations present ongoing challenges despite modern biosafety measures. Notably, LAIs attributed to inhaling infectious aerosols continue to occur.
Objective: This review aims to enhance understanding of the risks of LAIs associated with infectious aerosols.
J Appl Clin Med Phys
September 2025
Icon Cancer Centre Toowoomba, Toowoomba, Queensland, Australia.
Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.
Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.
PLoS One
September 2025
Centre for Experimental Pathogen Host Research, School of Medicine, University College Dublin, Dublin, Ireland.
Background: Acute viral respiratory infections (AVRIs) rank among the most common causes of hospitalisation worldwide, imposing significant healthcare burdens and driving the development of pharmacological treatments. However, inconsistent outcome reporting across clinical trials limits evidence synthesis and its translation into clinical practice. A core outcome set (COS) for pharmacological treatments in hospitalised adults with AVRIs is essential to standardise trial outcomes and improve research comparability.
View Article and Find Full Text PDFJ Anim Sci
September 2025
Department of Animal Science, South Dakota State University, Brookings, SD 57007, USA.
Flaxseed oil contains elevated levels of omega-3 fatty acids (n-3 FA), which have been shown to impact reproductive performance. This study aimed to determine the effects of a flaxseed oil-based supplement on reproductive parameters, feeding behavior, and lipid profile in beef heifers. Sixty Angus and Simmental × Angus heifers (14 months old ± 2 months), blocked by full body weight (BW; 396.
View Article and Find Full Text PDFJMIR Form Res
September 2025
Department of Critical Care Medicine, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangdong Provincial Geriatrics Institute, No. 106, Zhongshaner Rd, Guangzhou, 510080, China, 86 15920151904.
Background: Point-of-care ultrasonography has become a valuable tool for assessing diaphragmatic function in critically ill patients receiving invasive mechanical ventilation. However, conventional diaphragm ultrasound assessment remains highly operator-dependent and subjective. Previous research introduced automatic measurement of diaphragmatic excursion and velocity using 2D speckle-tracking technology.
View Article and Find Full Text PDF