A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Corneal subbasal nerve plexus reinnervation and stromal cell morphology with different cap thicknesses in small incision lenticule extraction. | LitMetric

Corneal subbasal nerve plexus reinnervation and stromal cell morphology with different cap thicknesses in small incision lenticule extraction.

Eye Vis (Lond)

Beijing Ophthalmology and Visual Sciences Key Lab, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.

Published: April 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The corneal cap thickness is a vital parameter designed in small incision lenticule extraction (SMILE). The purpose was to investigate the changes in corneal subbasal nerve plexus (SNP) and stromal cells with different cap thicknesses and evaluate the optimized design for the surgery.

Methods: In this prospective, comparative, non-randomized study, a total of 108 eyes of 54 patients who underwent SMILE were allocated into three groups with different corneal cap thicknesses (110 μm, 120 μm or 130 μm group). The SNP and stromal cell morphological changes obtained from in vivo corneal confocal microscopy (IVCCM) along with their refractive outcomes were collected at 1 week, 1 month, 3 months and 6 months postoperatively. One-way analysis of variance (ANOVA) was used to compare the parameters among the three groups.

Results: The SNPs in the three groups all decreased after surgery and revealed a gradual increasing trend during the 6-month follow-up. The values of the quantitative nerve metrics were significantly lower in the 110 μm group than in the 120 μm and 130 μm groups, especially at 1 week postoperatively. No difference was detected between the 120 μm and 130 μm groups at any time point. Both Langerhans cells and keratocytes were activated after surgery, and the activation was alleviated during the follow-up.

Conclusions: The SMILE surgeries with 110 μm, 120 μm or 130 μm cap thickness design achieved good efficacy, safety, accuracy and stability for moderate to high myopic correction while the thicker corneal cap was more beneficial for corneal nerve regeneration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11000360PMC
http://dx.doi.org/10.1186/s40662-024-00381-6DOI Listing

Publication Analysis

Top Keywords

120 μm 130 μm
16
cap thicknesses
12
corneal cap
12
corneal subbasal
8
subbasal nerve
8
nerve plexus
8
stromal cell
8
small incision
8
incision lenticule
8
lenticule extraction
8

Similar Publications