Diastolic function assessment with four-dimensional flow cardiovascular magnetic resonance using automatic deep learning E/A ratio analysis.

J Cardiovasc Magn Reson

Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden; Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden. Electronic address:

Published: June 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Diastolic left ventricular (LV) dysfunction is a powerful contributor to the symptoms and prognosis of patients with heart failure. In patients with depressed LV systolic function, the E/A ratio, the ratio between the peak early (E) and the peak late (A) transmitral flow velocity, is the first step to defining the grade of diastolic dysfunction. Doppler echocardiography (echo) is the preferred imaging technique for diastolic function assessment, while cardiovascular magnetic resonance (CMR) is less established as a method. Previous four-dimensional (4D) Flow-based studies have looked at the E/A ratio proximal to the mitral valve, requiring manual interaction. In this study, we compare an automated, deep learning-based and two semi-automated approaches for 4D Flow CMR-based E/A ratio assessment to conventional, gold-standard echo-based methods.

Methods: Ninety-seven subjects with chronic ischemic heart disease underwent a cardiac echo followed by CMR investigation. 4D Flow-based E/A ratio values were computed using three different approaches; two semi-automated, assessing the E/A ratio by measuring the inflow velocity (MVvel) and the inflow volume (MVflow) at the mitral valve plane, and one fully automated, creating a full LV segmentation using a deep learning-based method with which the E/A ratio could be assessed without constraint to the mitral plane (LVvel).

Results: MVvel, MVflow, and LVvel E/A ratios were strongly associated with echocardiographically derived E/A ratio (R = 0.60, 0.58, 0.72). LVvel peak E and A showed moderate association to Echo peak E and A, while MVvel values were weakly associated. MVvel and MVflow EA ratios were very strongly associated with LVvel (R = 0.84, 0.86). MVvel peak E was moderately associated with LVvel, while peak A showed a strong association (R = 0.26, 0.57).

Conclusion: Peak E, peak A, and E/A ratio are integral to the assessment of diastolic dysfunction and may expand the utility of CMR studies in patients with cardiovascular disease. While underestimation of absolute peak E and A velocities was noted, the E/A ratio measured with all three 4D Flow methods was strongly associated with the gold standard Doppler echocardiography. The automatic, deep learning-based method performed best, with the most favorable runtime of ∼40 seconds. As both semi-automatic methods associated very strongly to LVvel, they could be employed as an alternative for estimation of E/A ratio.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11058894PMC
http://dx.doi.org/10.1016/j.jocmr.2024.101042DOI Listing

Publication Analysis

Top Keywords

e/a ratio
44
e/a
12
ratio
12
deep learning-based
12
associated lvvel
12
peak
9
diastolic function
8
function assessment
8
cardiovascular magnetic
8
automatic deep
8

Similar Publications

Objective This research investigated the application of real-time, three-dimensional speckle tracking imaging (RT-3D-STI) to evaluate left atrial (LA) function in individuals suffering from hypertensive heart disease (HHD) and heart failure with preserved ejection fraction (HFpEF).Material and methods This retrospective study included 100 patients with HHD and HFpEF hospitalized from August 2023to June 2024 (HFpEF group). 100 healthy individuals undergoing physical examinations comprised the control group.

View Article and Find Full Text PDF

Background: Limited treatment options exist for infrapopliteal disease in patients with chronic limb-threatening ischemia (CLTI), a condition associated with a high risk of limb loss. Interventional management of diseased infrapopliteal vessels with percutaneous transluminal angioplasty (PTA) is associated with high rates of restenosis and reintervention. In the LIFE-BTK trial, the drug-eluting resorbable scaffold (DRS) demonstrated superior 12-month efficacy compared with PTA in a selected CLTI population with predominantly noncomplex, mildly to moderately calcified lesions.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the impact of asthma severity on biventricular cardiac functions using tissue Doppler imaging (TDI), two-dimensional speckle tracking echocardiography (2D-STE), and three-dimensional speckle tracking echocardiography (3D-STE).

Methods: Sixty-three children with asthma, aged between 5 and 16 years, were enrolled in the study along with 63 matched controls. All participants underwent cardiac assessments, including TDI, 2D-STE, 3D-STE, conventional echocardiography, and pulmonary function testing with spirometry.

View Article and Find Full Text PDF

The increasing pollution of water bodies from various industrial wastewater discharges has raised significant environmental concerns because these effluents contain toxic, nonbiodegradable compounds that pose serious risks to living organisms. In particular, the textile and pharmaceutical industries routinely use dyes that severely degrade water quality and lead to significant environmental issues. Therefore, effective removal of these dyes from industrial wastewater is crucial for mitigating pollution.

View Article and Find Full Text PDF

Standardization of larval bioassays for determination of fluralaner susceptibility in Rhipicephalus microplus.

Vet Parasitol

September 2025

Instituto de Pesquisas Veterinárias Desidério Finamor, Eldorado do Sul, Rio Grande do Sul, Brazil. Electronic address:

Fluralaner is an isoxazoline acaricide with potent activity against Rhipicephalus (Boophilus) microplus, a major tick species affecting cattle in South America. In this study, larval bioassays were performed to evaluate the baseline susceptibility of R. microplus populations from Brazil and Argentina to fluralaner.

View Article and Find Full Text PDF