Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Unsedated transnasal endoscopy (TNE) as transnasal esophagoscopy (TN-Eso) has emerged as a promising alternative to esophagogastroduodenoscopy (EGD) under sedation to assess eosinophilic esophagitis (EoE). We report our center's experience using single-use gastroscopes to perform sedation-free transnasal EGD (TN-EGD) with biopsies in an office-based setting.

Methods: A retrospective review was performed on patients with eosinophilic esophagitis who underwent office-based sedation-free TNE with topical analgesia and virtual reality (VR) procedural dissociation and distraction. A sterile, single-use, ultra-slim 3.5 mm outer diameter, 110 cm long gastroscope with 2 mm working channel (EvoEndo) was used to perform TNE with biopsies/brushings. Data including demographics, procedure success rate, total visit time, biopsy adequacy, procedure time, procedural preference, and complications were collected.

Results: Office-based TNE was completed in 8 patients (six males, age range 11-20 years). The endoscope was advanced by an experienced transoral endoscopist successfully through the nares into stomach (transnasal esophagogastroscopy [TN-EG]) in all subjects (100%) and into the duodenum (TN-EGD) in seven subjects (87.5%). Biopsies were obtained from esophagus in all cases and from the stomach/duodenum in five cases. Histological assessment, esophageal brushing, disaccharidase enzyme analysis, or duodenal aspirate analysis were performed as indicated. EoE reevaluation was the primary indication to perform endoscopy in all patients. Visual and histologic findings were all adequate for assessment. There were no significant adverse events.

Conclusion: Office-based TN-EGD with VR procedural distraction and dissociation using single-use gastroscopes was effective to monitor EoE, gastritis, and duodenitis in a pediatric practice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10964326PMC
http://dx.doi.org/10.1002/jpr3.12025DOI Listing

Publication Analysis

Top Keywords

single-use gastroscopes
12
office-based sedation-free
8
sedation-free transnasal
8
eosinophilic esophagitis
8
office-based
5
transnasal
5
transnasal esophagogastroduodenoscopy
4
esophagogastroduodenoscopy biopsies
4
single-use
4
biopsies single-use
4

Similar Publications

The trend toward disposable products in gastrointestinal endoscopy, including single-use endoscopes, remains undeterred, even though crucial questions of sustainability and performance have not been sufficiently studied. The first single-use therapeutic gastroscope was recently approved in Europe, but clinical data to support its use are currently lacking. We aimed to evaluate the performance of this novel device in routine procedures requiring a large working channel.

View Article and Find Full Text PDF
Article Synopsis
  • This study compares two methods for drying endoscopes after disinfection: a standard drying method (SD) using an endoscope washer-disinfector (EWD) and a novel drying method (ND) using a special device with laminar and turbulent airflow.
  • Results showed that the ND was more effective, with no residual water left in endoscope channels compared to 90% in the SD group, and significantly less bacterial contamination after 14 days.
  • The ND also reduced drying time from over 16 minutes to under 6 minutes, highlighting its efficiency and potential as a better alternative for reprocessing flexible endoscopes.
View Article and Find Full Text PDF

[This corrects the article DOI: 10.1055/a-2271-2303.].

View Article and Find Full Text PDF