Objectives: The objectives were to present the real-time estimated values of cochlear implant (CI) electrode insertion speed (IS) during intraoperative sessions using the Cochlear Nucleus SmartNav System to assess whether this measure affected CI outcomes and to determine whether real-time feedback assists expert surgeons in achieving slow insertion.
Methods: The IS was measured in 52 consecutive patients (65 implanted ears) using the CI632 electrode. The IS values were analyzed in relation to procedure repetition over time, NRT ratio, and CI audiological outcomes.
Results: The average IS was 0.64 mm/s (SD = 0.24); minimum and maximum values were 0.23 and 1.24 mm/s, respectively. The IS significantly decreased with each array insertion by the operator ( = 0.006), and the mean decreased by 24% between the first and last third of procedures; however, this reduction fell within the error range of SmartNav for IS (+/-0.48 mm/s). No correlation was found between IS and the NRT ratio ( = 0.51), pure-tone audiometry (PTA) at CI activation ( = 0.506), and PTA ( = 0.94) or word recognition score ( = 0.231) at last evaluation.
Conclusions: The estimated IS reported by SmartNav did not result in a clinically significant reduction in insertion speed or an improvement in CI hearing outcomes. Real-time feedback of IS could potentially be used for training, but its effectiveness requires confirmation through additional studies and more accurate tools. Implementation of IS assessment in clinical practice will enable comparisons between measurement techniques and between manual and robot-assisted insertions. This will help define the optimal IS range to achieve better cochlear implant (CI) outcomes.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961689 | PMC |
http://dx.doi.org/10.3390/audiolres14020021 | DOI Listing |
Bio Protoc
August 2025
Kenya Agricultural Livestock Research Organization, Nairobi, Kenya.
Transposon-based genetic transformation enables stable transgene integration in avian genomes and is increasingly used in the development of transgenic chickens for enhanced disease resistance, productivity, and biopharmaceutical applications. Conventional transformation techniques in avian biotechnology, including viral vectors and primordial germ cell (PGC) manipulation, are limited by biosafety risks, low efficiency, and technical complexity. This protocol outlines a two-step cloning approach for generating transposon-compatible gene constructs suitable for chicken embryo microinjection.
View Article and Find Full Text PDFBMC Bioinformatics
August 2025
School of Computer Science and Engineering, Sun Yat-sen University, Waihuan Dong Road, Guangzhou, 510006, China.
In the genome analysis workflow, Genome Analysis Toolkit (GATK) HaplotypeCaller is a widely used variant calling tool designed to accurately identify single nucleotide polymorphisms (SNPs) and insertions/deletions (Indels) in samples. However, when processing large-scale datasets, HaplotypeCaller often faces the challenge of excessively long runtime. Parallelizing GATK HaplotypeCaller with data segmentation is an effective solution, but existing methods struggle to accurately estimate the computational complexity of each data block, leading to severe computational skew.
View Article and Find Full Text PDFJBJS Essent Surg Tech
August 2025
Department of Orthopaedics, Faculty of Medicine, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada.
Background: Over the last 30 years, total ankle arthroplasty (TAA) has become a viable surgical option for end-stage ankle arthritis. The aim of TAA is to relieve pain and preserve ankle joint range of motion, which, by definition, shields adjacent joints. Alignment is essential for the longevity and survival of TAA, since malalignment of TAA components can cause abnormal loading patterns with subsequent polyethylene wear and early implant failure.
View Article and Find Full Text PDFSensors (Basel)
July 2025
Humanoid and Cognitive Robotics Lab, Jožef Stefan Institute, 1000 Ljubljana, Slovenia.
In this paper, we propose an active touch sensing algorithm designed for robust hole localization in 3D objects, specifically aimed at assembly tasks such as peg-in-hole operations. Unlike general object detection algorithms, our solution is tailored for precise localization of features like hole openings using sparse tactile feedback. The method builds on a prior 3D map of the object and employs a series of iterative search algorithms to refine localization by aligning tactile sensing data with the object's shape.
View Article and Find Full Text PDFThe proliferation of inverse design techniques in photonics integrated circuits (PICs) has expanded the scope of applications for the adjoint method, particularly in developing ultra-compact and efficient on-chip integrated components. Here, we demonstrate the design and implementation of advanced polarization control systems with high-speed performance. The design employed an inverse-designed ultra-compact polarization beam rotator-splitter (PBRS) with a high-speed PN junction phase shifter in a silicon photonics platform.
View Article and Find Full Text PDF