Article Abstract

Background: The term "navigation" describes a device that can pinpoint critical anatomical features, the most direct path to the target, and the optimal surgical orientation. This study aimed to conduct a comprehensive literature search on computer-assisted navigation for use in oral and maxillofacial surgery.

Methods: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement, relevant studies were retrieved from five electronic databases: Medline, Web of Science, PubMed, Google Scholar, and Saudi Digital Library (SDL). The central question was, "Does the computer-assisted navigation system improve the outcome of surgical procedures in the oral and maxillofacial region?" The Cochrane Risk of Bias 2 was used to determine the various types of bias.

Results: Post-traumatic midfacial reconstruction is one of the many fields that have benefited from the use of computer-assisted navigation because of its reliability. It can also be used to extricate difficult foreign entities from the operative zone. Locating critical anatomical components, communicating the surgical plan to the patient, and verifying surgical success can improve the function and appearance of patients with dentofacial abnormalities. In addition, it decreases the surgical error margin and duration.

Conclusion: Computer-assisted navigation is promising in surgical practice. The accuracy of surgery can be significantly enhanced by first planning the process in a virtual environment and then performing it under close supervision in real time. In addition, the time required for preoperative planning and surgery can be reduced by creating and improving software programs.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10960148PMC
http://dx.doi.org/10.1016/j.sdentj.2023.12.002DOI Listing

Publication Analysis

Top Keywords

computer-assisted navigation
20
oral maxillofacial
12
navigation oral
8
critical anatomical
8
surgical
6
computer-assisted
5
maxillofacial surgery
4
surgery systematic
4
systematic review
4
review background
4

Similar Publications

Purpose: To compare the accuracy of static guided surgery using a pilot drill guide and dynamic guided surgery for dental implant placement.

Materials And Methods: Partially edentulous adult patients requiring implant placement were randomly assigned to either the static guided surgery group using a pilot drill guide or the dynamic guided surgery group. Digital implant planning was conducted using intraoral scans and CBCT with planning software to determine the optimal prosthetic position.

View Article and Find Full Text PDF

Computer-assisted surgery and planning in percutaneous pelvic screw fixation.

Orthop Traumatol Surg Res

September 2025

CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.

Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.

View Article and Find Full Text PDF

Background: Low-field MRI provides superior soft-tissue contrast compared to CT while costing significantly less than high-field MRI, which makes it a more accessible option for MRI-guided radiation therapy planning. Four-dimensional MRI (4D-MRI) is a technique that has been increasingly adopted clinically for internal target volume (ITV) delineation in free-breathing liver radiotherapy planning, and it requires high spatial resolution and accurate respiratory phase differentiation to enable precise dose planning. The feasibility of 4D-MRI at low-field strength, specifically at 0.

View Article and Find Full Text PDF

Hybrid pneumatic-hydraulic actuation for MRI-guided robotic stereotactic neurointervention.

Sci Adv

September 2025

Shanghai Key Laboratory of Flexible Medical Robotics, Tongren Hospital, Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai 200336, China.

Stereotactic neurointervention is a common procedure for biopsy, injection, ablation, and implantation of electrodes for deep brain stimulation. Guided by preoperative imaging, conventional approaches are mostly performed manually, lacking operation stability and interactive feedback. The intraoperative magnetic resonance imaging (MRI) guidance enables both structural and functional assessment during operation, permitting interactive adaptation to tissue deformation and avoidance of critical anatomical regions.

View Article and Find Full Text PDF

Patellar instability remains one of the most challenging and persistent complications following total knee arthroplasty (TKA), significantly affecting patient satisfaction and functional outcomes. Despite advances in implant technology and surgical techniques, patellofemoral maltracking remains a leading cause of anterior knee pain and one of the most frequent non-infectious reasons for revision surgery. The etiology is complex and often involves a combination of component malposition, soft-tissue imbalance, patient-specific anatomical risk factors, and suboptimal implant design.

View Article and Find Full Text PDF