Evaluating Static Bone Cysts (SBCs) Through Long-Term Volumetric Analysis Using CBCT: A Study with 6-Month Follow-Up.

J Clin Exp Dent

Head of Department. Department of Oral Pathology & Microbiology. School of Dental Sciences, Sharda University, Greater Noida, U.P. - 201310.

Published: February 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Salivary gland bone defects are static lesions which are rare entities, generally asymptomatic and found in routine imaging exams. However, in atypical cases or when misdiagnosed, surgical intervention is carried out. Purpose: a) The study is intended to investigate the frequency of SBC's and to describe the radiological characteristics of its subtypes; b) To evaluate the efficacy of volumetric analysis tool in CBCT and; c) To describe the confirmative role of CBCT in the diagnosis of SBC's without the need for surgical intervention.

Material And Methods: The study was conducted on 11 subjects with SBC detected on 3304 panoramic radiographs. CBCT images for each patient were captured at baseline and at an interval of 6 months. Radiographic sub-types of SBC based on the relationship to mandibular canal and bucco-lingual expansion were studied. Files in DICOM format were transferred into OnDemand 3D program (Cybermed Co, Seoul, Korea) and volumes in mm3 of the cavities were measured by 2 observers at both intervals. Inter and intra reliability of volumetric measurements between observers was compared using correlation coefficient and student t test.

Results: There were 8 males and 3 females who had SBC in this study (age range: 22-70 years). According to the relationship of SBC with mandibular canal, most SBCs were Type 1 (63.5 %) followed by Type 2 & 3 (18.5 %) each. The total volume of SBC in patients ranged from 146 mm3 to 650 mm3 (mean: 332.5 mm3). There was no significant difference between observers for volume measurements at baseline and at 6 months interval (>0.05).

Conclusions: Based on the results of this study, CBCT should be considered as a definitive diagnostic modality for volumetric analysis of SBCs. Over diagnosis, unnecessary surgical exploration and agony to patients can be avoided using this tool. Stafne bone cavity, CBCT, Volumetric analysis, salivary gland, panoramic radiography.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10943685PMC
http://dx.doi.org/10.4317/jced.61099DOI Listing

Publication Analysis

Top Keywords

volumetric analysis
16
salivary gland
8
mandibular canal
8
cbct
6
volumetric
5
study
5
sbc
5
evaluating static
4
static bone
4
bone cysts
4

Similar Publications

Evaluating the Long-term Effects of Microfocused Ultrasound on Facial Tightening Using Quantitative Instruments: Efficacy and Safety.

Aesthetic Plast Surg

September 2025

Department of Plastic Surgery, The First Affiliated Hospital, Jinan University, No. 613 West, Huangpu Avenue, Guangzhou, 510630, Guangdong Province, China.

Background: Microfocused ultrasound (MFU) is a non-invasive technique used for facial rejuvenation, yet there is limited quantitative data on its long-term effects. This study aimed to evaluate the long-term efficacy and safety of MFU for facial rejuvenation. We utilized standardized photography along with advanced skin assessment technologies to analyze the impact of MFU on facial morphology, skin function, and patient satisfaction over a 12-month period.

View Article and Find Full Text PDF

Purpose: This study aimed to evaluate the performance of 3D-printed denture base resins (DBRs) compared with conventionally printed DBRs, examine their biofilm formation and physical properties, and determine the viability of 3D-printed DBRs as a superior alternative in removable prosthodontics.

Methods: The DBR samples were fabricated using traditional packing (TRA), milling (MIL), and 3D printing (3DP) methods. All samples were serially polished with an abrasive paper.

View Article and Find Full Text PDF

Introduction: Total hip arthroplasty (THA) with third-generation alumina ceramic heads on highly cross-linked polyethylene liners (HXLPE) has demonstrated excellent outcomes in young patients. However, concerns of ceramic head fracture, squeaking, stripe wear, and limited sizing led to the development of a fourth-generation ceramic head. The purpose of our study was to report on survivorship, wear characteristics, and patient-reported outcomes of THA with a fourth-generation 32-mm ceramic femoral head and HXLPE liner in patients 50 years or younger at 10-year minimum follow-up.

View Article and Find Full Text PDF

Introduction: Interpretation and analysis of magnetic resonance imaging (MRI) scans in clinical settings comprise time-consuming visual ratings and complex neuroimage processing that require trained professionals. To combat these challenges, artificial intelligence (AI) techniques can aid clinicians in interpreting brain MRI for accurate diagnosis of neurodegenerative diseases but they require extensive validation. Thus, the aim of this study was to validate the use of AI-based AQUA (Neurophet Inc.

View Article and Find Full Text PDF

Systematic review of prospective hazard analysis in radiation therapy.

Med Phys

September 2025

Image X Institute, Faculty of Medicine and Health, University of Sydney, Eveleigh, New South Wales, Australia.

Introduction: Prospective hazard analysis (PHA) was introduced to the wider medical physics community by the initiation of American association of physicists in medicine task group 100 in 2003. Since then, there has been increasing interest in the applicability of PHA to radiotherapy for the purpose of keeping patients safe and assessing the risks within the whole practice of radiotherapy. The purpose of this research was to review the PHA literature focusing on which techniques and technologies have been assessed, how they have been assessed, and what can be learnt.

View Article and Find Full Text PDF