Article Abstract

The longevity of current joint replacements is limited by aseptic loosening, which is the primary cause of non-infectious failure for hip, knee, and ankle arthroplasty. Aseptic loosening is typically caused either by osteolysis from particulate wear, or by high shear stresses at the bone-implant interface from over-constraint. Our objective was to demonstrate feasibility of a compliant intramedullary stem that eliminates over-constraint without generating particulate wear. The compliant stem is built around a compliant mechanism that permits rotation about a single axis. We first established several models to understand the relationship between mechanism geometry and implant performance under a given angular displacement and compressive load. We then used a neural network to identify a design space of geometries that would support an expected 100-year fatigue life inside the body. We additively manufactured one representative mechanism for each of three anatomic locations, and evaluated these prototypes on a KR-210 robot. The neural network predicts maximum stress and torsional stiffness with 2.69% and 4.08% error respectively, relative to finite element analysis data. We identified feasible design spaces for all three of the anatomic locations. Simulated peak stresses for the three stem prototypes were below the fatigue limit. Benchtop performance of all three prototypes was within design specifications. Our results demonstrate the feasibility of designing patient- and joint-specific compliant stems that address the root causes of aseptic loosening. Guided by these results, we expect the use of compliant intramedullary stems in joint reconstruction technology to increase implant lifetime.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10939320PMC
http://dx.doi.org/10.1109/JTEHM.2024.3365305DOI Listing

Publication Analysis

Top Keywords

compliant intramedullary
12
aseptic loosening
12
intramedullary stems
8
stems joint
8
joint reconstruction
8
particulate wear
8
demonstrate feasibility
8
neural network
8
three anatomic
8
anatomic locations
8

Similar Publications

The Kuntscher nail, once a pioneering solution for femoral shaft fracture fixation, has largely fallen out of use with the emergence of modern interlocking intramedullary systems. However, retained Kuntscher nails may still be encountered in older patients and can pose significant technical challenges when removal is required, especially in cases of incarceration. Standard closed extraction methods are often ineffective, necessitating alternative surgical strategies.

View Article and Find Full Text PDF

Background: Enhanced Recovery After Surgery (ERAS) has been extensively applied across numerous surgical specialties. However, there remains a paucity of research regarding the implementation of ERAS in advanced age patients (≥75 years) who undergo InterTAN nail surgery for intertrochanteric femoral fractures (ITF). This study aimed to assess if our ERAS protocol improves satisfaction and clinical outcomes in such patients.

View Article and Find Full Text PDF

Advancements in fracture fixation have significantly reshaped orthopedic trauma management by improving mechanical stability and promoting biological healing. This retrospective observational study assessed clinical and biomechanical outcomes in 500 patients who underwent surgical fixation for radiologically confirmed fractures. Patients were categorized into two groups: Group A received conventional fixation methods (e.

View Article and Find Full Text PDF

Introduction Pertrochanteric femur fractures comprise approximately half of all hip fractures. The proximal femoral nail anti-rotation 2 (PFNA2), designed by Arbeitsgemeinschaft fur Osteosynthesefragen (AO), is an intramedullary device with a helical blade rather than a screw for better purchase in the femoral head. This modification in the proximal femur nail (PFN) was done to adapt to the Asian population and reduce nail-related complications in the Asian population.

View Article and Find Full Text PDF

This case report presents the treatment of a 13-year-old male patient diagnosed with high-grade osteosarcoma of the proximal tibia. Management involved a combination of transphyseal resection, extracorporeal irradiation, and reconstruction using a vascularized fibula autograft. The tumor was excised with clear margins, as confirmed intraoperatively through frozen section analysis.