A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of the Stability of Internal Fixation Constructs in a Low Distal Tibia Extra-articular Cadaveric Fracture Model: A Comparative Biomechanical Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction Despite the recent advances in implant design, the choice of an internal fixation modality for extra-articular distal tibia fractures remains controversial, and there is sparse literature comparing the stability of intramedullary nails and locked plates for such fractures. Hence, we conducted a biomechanical study on an AO type 43A3 tibia fracture cadaveric model stabilized by four different constructs, viz., intramedullary (IM) interlocking nail, anteromedial plate, anterolateral plate, and posterior plate. An AO type 43A3 fracture is defined as an extra-articular fracture of the distal tibia with metaphyseal comminution. Methods A biomechanical comparative study on formalin-preserved human cadaveric tibiae was undertaken; a total of four groups were tested, with eight bones in each group. Out of the 32 cadaveric tibiae, 19 bones belonged to male cadavers, and 13 bones belonged to female cadavers. All bones were dissected from age-appropriate cadavers and fixed with an implant, followed by the creation of a 1 cm osteotomy to simulate an AO type 43A3 fracture. All fixation constructs were subjected to three-point bending tests in the anteroposterior (AP) and mediolateral (ML) planes. Three parameters, viz., bending stiffness, peak fracture gap angle, and neutral zone, were evaluated on the load-displacement curves. A fixation construct was deemed biomechanically stable if it had a high bending stiffness, a low neutral zone (inherent toggle in the construct by its weight), and a low peak fracture gap angle. Results Out of the four implants tested, locked IM nails exhibited the maximum biomechanical stability in terms of higher bending stiffness, smaller peak fracture gap angle, and smaller neutral zones. The IM nail exhibited the highest bending stiffness in the AP plane, and the anterolateral plate had the lowest bending stiffness, and the difference was statistically significant (p= 0.032). In the AP plane, the anterolateral plate exhibited a bending stiffness of 1.51 ± 0.69 Nm/degree, whereas the intramedullary nail exhibited a bending stiffness of 2.34 ± 0.81 Nm/degree, and the posterior locked plate had a bending stiffness of 1.57 ± 0.44 Nm/degree. In the ML plane, the anterolateral plate exhibited the highest neutral zone as compared to the intramedullary nail, which had the lowest neutral zone, and the difference was statistically significant (p = 0.019). The intramedullary nail exhibited the lowest neutral zone of 0.46 ± 0.31 degrees, whereas the posterior locked plate exhibited a neutral zone of 0.78 ± 0.43 degrees in the ML plane. The anterolateral plate exhibited a neutral zone of 1.43 ± 1.00 (expressed as mean ± SD) degrees in the mediolateral plane. Conclusion Our biomechanical study supports the recommendations of using a locked intramedullary nail for AO type 43A3 fractures. We concluded that the anterolateral plate construct exhibited the least biomechanical stability, in terms of lower AP bending stiffness and higher neutral zone. If the surgeon must choose a locked plating technique for any reason, the anterolateral locking plate should be avoided. If plating is at all required, we can recommend both anteromedial and posterior locked plating as biomechanically sound options.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10934011PMC
http://dx.doi.org/10.7759/cureus.54033DOI Listing

Publication Analysis

Top Keywords

bending stiffness
32
neutral zone
32
anterolateral plate
24
type 43a3
16
plane anterolateral
16
plate exhibited
16
intramedullary nail
16
distal tibia
12
biomechanical study
12
peak fracture
12