Objective: The aim of this study was to validate the use of a new resection device in patient candidates for surgical aortic valve replacement. We evaluated the efficacy of this new circular blade to resect the aortic valve and the efficacy to collect the debris during the resection.
Methods: For this study, a single size instrument was used, with an external diameter of 22 mm, and patients were selected on the basis of the preoperative assessment of the aortic diameters.
Results: From October 2018 to June 2019, 10 patient candidates for surgical aortic valve replacement were selected to undergo native aortic valve resection using a new device, before surgical valve implantation. The mean age of the patients was 74 ± 7.6 years, and 8 of 10 were male. The mean aortic annulus diameter, measured before the procedure, was 25.7 ± 1.57 mm. The resection was complete in 9 (90%) patients. In 1 patient, due to an imprecise positioning of the device, the valve resection was partial. None of the patients showed signs or symptoms due to debris embolism. In all patients, the postoperative course was uneventful.
Conclusions: These preliminary results show that resection of the aortic valve using a circular foldable blade is feasible. This prototype, used during conventional surgery even through a small incision, provided an efficient tool to easily resect the valve without debris release.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/15569845241232645 | DOI Listing |
Eur Heart J Case Rep
September 2025
Department of Cardiology, Toyohashi Heart Center, 21-1 Gobutori, Oyamacho, Toyohashi 441-8530, Japan.
Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel - Vrije Universiteit Brussel, European Reference Networks Guard-Heart, 1090 Brussels, Belgium.
Despite continued advancements in transcatheter aortic valve implantation (TAVI) techniques, the incidence of permanent pacemaker implantation (PPI) remains substantial. Established predictors of PPI include advanced age, pre-existing electrocardiographic conduction abnormalities, prosthetic valve type, implantation depth, and anatomical parameters, such as membranous septum length, which are currently under active investigation. In routine clinical practice, the management strategy often involves the temporary placement of a transvenous pacemaker lead, followed by a period of observation.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
Department of Cardiology, Harbin Medical University, 150000 Harbin, Heilongjiang, China.
Background: Differences between female and male patients may influence the outcomes of transcatheter aortic valve replacement (TAVR). However, knowledge regarding known sex differences in TAVR procedures among Chinese people remains limited. Therefore, this study aimed to investigate the impact of sex-related differences on reverse left ventricular (LV) remodeling following TAVR in the Chinese population.
View Article and Find Full Text PDFRev Cardiovasc Med
August 2025
E. Meshalkin National Medical Research Center, Institute of Cardiovascular Pathology Research, 630055 Novosibirsk, Russian Federation.
Background: Presently, the availability of single-stage surgical correction of mitral valve disease combined with atrial fibrillation (AF) via a mini-access approach remains limited. Moreover, the comparative effectiveness of this procedure versus conventional sternotomy (CS) remains poorly understood. Thus, this study aimed to conduct a comparative assessment of the efficacy and safety of concomitant mitral valve surgery and AF ablation via a minimally invasive approach (minimally invasive cardiac surgery, MICS group) versus the standard sternotomy approach (CS group).
View Article and Find Full Text PDFFront Cardiovasc Med
August 2025
Department of Cardiovascular Medicine, The First Hospital of Jilin University, Changchun, China.
Due to the low incidence of cardiovascular involvement in syphilis, there are currently no established consensus or guidelines for managing such cases. The patient, with no coronary artery disease risk factors, presented with chest pain and heart failure (HF). Emergency coronary angiography revealed severe stenosis of the bilateral coronary ostia, with smooth intimal lining in the remaining coronary arteries.
View Article and Find Full Text PDF