A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Spectral computed tomography angiography using a gadolinium-based contrast agent for imaging of pathologies of the aorta. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: Especially patients with aortic aneurysms and multiple computed tomography angiographies (CTA) might show medical conditions which oppose the use of iodine-based contrast agents. CTA using monoenergetic reconstructions from dual layer CT and gadolinium (Gd-)based contrast agents might be a feasible alternative in these patients. Therefore, the purpose of this study was to evaluate the feasibility of clinical spectral CTA with a Gd-based contrast agent in patients with aortic aneurysms.

Methods: Twenty-one consecutive scans in 15 patients with and without endovascular aneurysm repair showing contraindications for iodine-based contrast agents were examined using clinical routine doses (0.2 mmol/kg) of Gd-based contrast agent with spectral CT. Monoenergetic reconstructions of the spectral data set were computed.

Results: There was a significant increase in the intravascular attenuation of the aorta between pre- and post-contrast images for the MonoE40 images in the thoracic and the abdominal aorta (p < 0.001 for both). Additionally, the ratio between pre- and post-contrast images was significantly higher in the MonoE40 images as compared to the conventional images with a factor of 6.5 ± 4.5 vs. 2.4 ± 0.5 in the thoracic aorta (p = 0.003) and 4.1 ± 1.8 vs. 1.9 ± 0.5 in the abdominal aorta (p < 0.001).

Conclusions: To conclude, our study showed that Gd-CTA is a valid and reliable alternative for diagnostic imaging of the aorta for clinical applications. Monoenergetic reconstructions of computed tomography angiographies using gadolinium based contrast agents may be a useful alternative in patients with aortic aneurysms and contraindications for iodine based contrast agents.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11147857PMC
http://dx.doi.org/10.1007/s10554-024-03074-2DOI Listing

Publication Analysis

Top Keywords

contrast agent
12
contrast agents
12
gd-based contrast
12
computed tomography
8
patients aortic
8
iodine-based contrast
8
monoenergetic reconstructions
8
contrast
6
spectral
4
spectral computed
4

Similar Publications